background image

3. Maintenance

42

031-132-B0-001 Rev. A

TM

©2000

3.5

PAD SHEAR Magnetic Switch and Water Intrusion Float

Allow 15 minutes for completion of procedure

Tools required:

3/8”-1/4”-5/16” wrenches

Wire cutters

Phillips screwdriver

Removal and replacement procedure:

1.

Remove the APU housing access panel.

2.

Locate and remove the switch and float mounting bracket as shown below.

Location of bracket mounting nut (3/8”)

in lower portion of APU housing.

The pad shear switch and water

intrusion float bracket is located on the

outside of the APU housing.

Remove bracket bolt with a 5/16”

wrench. Set mounting hardware aside.

Advertising