018-332-C0-002 Rev. B

1. System Overview

© 2001

TM

Figure 1-5; ECM Port on SSC

Figure 1-6; ECM COMM Port

2
1

4

3

Top of ECM

2

1 3

4

1.2.5 Serial Communications Interfaces, continued

1.2.5.4 ECM Port

This interface connects the SSC to the Engine Control Module

(ECM) in an AlphaGen generator system. The SSC coordinates

all generator activity and status monitoring through this

interface.

The ECM port is a 4-pin terminal block:

Pin #

Description

1

ECM » 8V

2

+ RS-485

3

- RS-485

4

ECM Ground

Note: When Alpha standard cable is not used for the ECM

connection, it is necessary to install the opposite end

of the non-Alpha cable into the ECM, at the port labeled

COMM. To do this, install wire #1 into pin-out #1 on the

terminal block, using a small slotted screwdriver. (Verify

that the same wire numbers are used in both ends of the

connection.) Install wires 2 through 4 in the same

manner.

Note: The ECM connection is separate and isolated from the

power supply internal bus, and has its own connector.