Model Number Description

Digit 1, 2, 3 – Model

EZT

Single Duct

Digit 4 – Unit Type

S Standard
A

With integral sound attenuator

E

Extended unit for electric coil

Digit 5, 6 – Inlet Size

05

5 inch

10

10 inch

06

6 inch

12

12 inch

07

7 inch

14

14 inch

08

8 inch

16

16 inch

09

9 inch

24

24 x 16 inch rectangular

Digit 7 – Casing Construction

A

22 gauge steel (standard)

B

20 gauge steel

C

Fibre-Lok 22 gauge steel liner (metal covering
insulation edges)

D

Fibre-Lok 20 gauge steel liner (metal covering
insulation edges)

E

22 gauge steel double wall (inner liner over 1/2 inch
insulation)

F

22 gauge steel low temperature casing

Digit 8 – Insulation and Treatment

0

None

1

1/2 inch matte-faced glass fiber (standard)

2

1 inch matte-faced glass fiber (required with low
temperature casing)

3

1/2 inch foil-faced glass fiber (tape covering
insulation edges)

4

1 inch foil-faced glass fiber (tape covering insulation
edges)

5

3/8 inch closed cell (fiber free)

Digit 9 – Control Type

0 None
P

Pneumatic - Pressure independent

N

Pneumatic - Pressure dependent

A

Electronic Analog - Pressure independent

E

Electric - Pressure dependent

F

Factory mounted, provided by others

Digit 10, 11, 12, 13 – Control Package Number

0000

None

XXXX Refer to pages 314 thru 317

Digit 14 – Control Location (determined by facing the inlet)

R

Right hand (standard)

L

Left hand

Digit 15, 16, 17, 18 – Minimum Airflow

0000

None specified

XXXX Specify minimum airflow setting in CFM

Refer to pages 314 and 316

Digit 19, 20, 21, 22 – Maximum Airflow

0000

None specified

XXXX Specify maximum airflow setting in CFM

Refer to pages 314 and 316

Digit 23 – Heating Coil and Connection Location
(determined by facing the inlet)

0

None

A

One-row hot water - right hand connection

B

One-row hot water - left hand connection

C

Two-row hot water - right hand connection

D

Two-row hot water - left hand connection

G

Four-row hot water - right hand connection

H

Four-row hot water - left hand connection

J

Electric Coil - right hand connection

K

Electric Coil - left hand connection

Digit 24 – Line Voltage Transformer

0 None
1

120 Volt/ 1 phase/ 60 Hz

2

208 Volt/ 1 phase/ 60 Hz

3

240 Volt/ 1 phase/ 60 Hz

4

277 Volt/ 1 phase/ 60 Hz

Digit 25 – Electric Coil Voltage and Steps
(location same as controls)

0

None

A

208 Volt/ 1 Phase/ 60 Hz 1 Step

B

208 Volt/ 1 Phase/ 60 Hz 2 Step

C

208 Volt/ 1 Phase/ 60 Hz 3 Step

D

240 Volt/ 1 Phase/ 60 Hz 1 Step

E

240 Volt/ 1 Phase/ 60 Hz 2 Step

F

240 Volt/ 1 Phase/ 60 Hz 3 Step

G

277 Volt/ 1 Phase/ 60 Hz 1 Step

H

277 Volt/ 1 Phase/ 60 Hz 2 Step

J

277 Volt/ 1 Phase/ 60 Hz 3 Step

K

208 Volt/ 3 Phase/ 60 Hz 1 Step

L

208 Volt/ 3 Phase/ 60 Hz 2 Step

M

208 Volt/ 3 Phase/ 60 Hz 3 Step

N

480 Volt/ 3 Phase/ 60 Hz 1 Step

P

480 Volt/ 3 Phase/ 60 Hz 2 Step

R

480 Volt/ 3 Phase/ 60 Hz 3 Step

S

120 Volt/ 1 Phase/ 60 Hz 1 Step

T

120 Volt/ 1 Phase/ 60 Hz 2 Step

U

120 Volt/ 1 Phase/ 60 Hz 3 Step

V

240 Volt/ 3 Phase/ 60 Hz 1 Step

W

240 Volt/ 3 Phase/ 60 Hz 2 Step

X

240 Volt/ 3 Phase/ 60 Hz 3 Step

Y

480 Volt/ 1 Phase/ 60 Hz 1 Step

Z

480 Volt/ 1 Phase/ 60 Hz 2 Step

1

480 Volt/ 1 Phase/ 60 Hz 3 Step

Digit 26, 27, 28 – Electric Coil KW

000

None

XXX

(in 0.5 KW increments)

Digit 29 and over – Options & Accessories

Access options
A1

6” x 6” Bottom access plate (provided with same
insulation as the casing)

A2

6” x 6” Bottom access door w/hinge and camlock

A3

6” x 6” Bottom removable access door with 2
camlocks

B1

6” x 6” Side access plate (provided with same
insulation as the casing on opposite side of controls)

B2

6” x 6” Side access door w/hinge and camlock
(opposite side of controls)

B3

6” x 6” Side removable access door with 2 camlocks
(opposite side of controls)

Casing options
C1

Unit mounting brackets – shipped loose

C2

Manual damper locking quadrant

C3

Standard Control Enclosure

C4

Universal (larger) control enclosure (must be opposite
electric coil connection side)

C5

Hinged front panel for control enclosure

LL

Lo-Leakage casing (available with only A3 or B3
access doors.

Electric control options
D1

Low voltage control disconnect switch

D2

Low voltage fuse and fuse block

D3

Line voltage SPST disconnect switch (120/1,
277/1 line voltage)

D4

Line voltage DPST disconnect switch (208/1, 230/1,
240/1 line voltage)

D5

Line voltage power-fusing (fuse and fuse block for
120/1, 277/1 line voltage)

D6

Line voltage power-fusing (fuse and fuse block for
208/1, 230/1, 240/1 line voltage)

D9

24 VAC actuator (3 wire / tri-state / fail in place)

Electric heat options
E1

Door interlocking disconnect switch - non-fused

E2

Mercury de-energizing contactors

E3

Power-fusing (Fuses and fuse blocks)

E5

Primary fused transformer

Notes:
Z in any digit indicates a non-catalog special which
requires authorization