Analyzer performance

Frequency specifications

Frequency range

2.381 to 2.519 GHz (Options 505 and 506)
4.800 to 5.875 GHz (Option 506 only)

Frequency resolution

250 kHz

Measurement bandwidth

Switchable between 22 and 40 MHz

Frequency accuracy

As VSG hardware performance

Phase Noise

10 kHz: < 87 dBc/Hz (nominal)

100 kHz: < 100 dBc/Hz (nominal)

Amplitude specifications

Input amplitude range

+23 to -70 dBm

Absolute power
measurement accuracy

2.381 to 2.519 GHz:
±0.6 dB (CW) (+23 to -50 dBm)

±0.3 dB (CW) typical (+23 to -70 dBm)

4.800 to 5.875 GHz:
±0.8 dB (CW) (+23 to -50 dBm)

±0.35 dB (CW) typical (+23 to -50 dBm)

RF input VSWR

< 1.6:1 (return loss: > 12.5 dB); 2.381 to 2.519 GHz
< 1.8:1 (return loss: > 10 dB); 4.800 to 5.875 GHz

Signal-to-Noise Ratio (SNR) >65 dB typical for 22 MHz bandwidth (2.381 to 2.519

GHz)
>52 dB for 22 MHz bandwidth (4.800 to 5.875 GHz)

Modulation specifications

Residual error vector
magnitude (EVM)

802.11a: 5 GHz band; 54 Mbps 64QAM OFDM: <-36 dB
(< 1.5%), power range +5 to -20 dBm
802.11b: DSSS: <-30 dB (< 3.0%), power range +5 to -30
dBm; equalization off
802.11b: DSSS: <-40 dB (< 1.0%), power range +5 to -30
dBm; equalization on
802.11g: 2.4 GHz band; 54 Mbps 64QAM OFDM: <-43 dB
(< 0.7%), power range +5 to -30 dBm
802.11n: 5 GHz band; 54 Mbps 64QAM OFDM; MCS7:
<-34 dB (< 2.0%), power range +5 to -20 dBm

Source performance

Frequency specifications

Frequency range

2.402 to 2.484 GHz (Options 505 and 506)
4.800 to 5.875 GHz (Option 506 only)

Frequency accuracy

As VSG hardware performance

Amplitude specifications for the RF In/Out port

Output amplitude range

1

2.402 to 2.484 GHz: +10 to -100 dBm (CW);
4.8 to 5.875 GHz: +3 to -100 dBm (CW);
See EVM specification for information on modulated
signals

Absolute amplitude
accuracy

2

2.402 to 2.484 GHz: ±0.6 dB (CW) typical (0 to -90 dBm)

4.8 to 5.875 GHz: ±0.8 dB (CW) typical (0 to -90 dBm)

1

This specification applies to instruments serial prefix MY4832 or greater, otherwise the specification is 2.402 to

2.484 GHz: 0 to -100 dBm (CW); 4.8 to 5.875 GHz: -4 to -100 dBm (CW)

2

This specification applies to instruments serial prefix MY4832 or greater, otherwise the specification is 2.402 to

2.484 GHz: ±0.6 dB (CW) typical (-10 to -90 dBm); 4.8 to 5.875 GHz: ±0.8 dB (CW) typical (-10 to -90 dBm)