Atec Doble-F6150 User Manual

F6150, Technical specifications total sources, Convertible sources

Advertising
background image

F6150

Over 10,000 Doble

®

protection test

instruments are currently used by
test engineers around the world,
to ensure the reliability of electric
power systems.

Technical SpeciFicaTionS

Total Sources

The F6150 can provide up to twelve simultaneous user configurable AC/DC sources
including: six convertible sources and six current sources.

convertible Sources

Each 150 VA Convertible Source can be used as a voltage source or optionally as a
high-power, low range current source. The F6150 has up to six Convertible Sources.

Source configurations

Output Power

Continuous

Transient for 1.5 Seconds

Number of Sources

75 VA

97.5 VA

6

150 VA

195 VA

3

300 VA

390 VA

2x150 VA or 1x150 VA+2x75 VA

450 VA

585 VA

1

Each 150 VA convertible source can be split into two 75 VA sources.
Two 150 VA convertible sources can be combined in parallel into one 300 VA current source.
Three 150 VA convertible sources can be combined in parallel into one 450 VA current source.

Ranges and Resolution

75 Va Source

F6150 Ranges (Resolution)

AC Voltage

75, 150 V rms (0.01V)

DC Voltage

106, 212 V dc (0.01V)

ac current
Transient

0.75, 1.5 A rms (0.0001
A)

Continuous

0.5, 1.0 A rms

(0.0001 A)

Dc current
Transient

0.53, 1.06 A dc (0.0001
A)

Continuous

0.354, 0.707 A dc
(0.0001 A)

150 Va Source

F6150 Ranges (Resolution)

AC Voltage

75, 150, 300 V rms
(0.01 V)

DC Voltage

106, 212 V (0.01 V), 300
VDC (0.1 V)

ac current
Transient

0.75, 1.5, 3.0 A rms
(0.0001 A)

Continuous

0.5, 1.0, 2.0 A rms
(0.0001 A)

Dc current
Transient

0.53, 1.06 (0.0001 A),
2.12 A dc (0.001 A)

Continuous

0.354, 0.707 (0.0001 A),
1.41 A dc (0.001 A)

300 Va Source

F6150 Ranges (Resolution)

ac current
Transient

1.5, 3.0, 6.0 A rms
(0.001 A)

Continuous

1.0, 2.0, 4.0 A rms
(0.001 A)

Dc current
Transient

1.06 A (.0.0001 A), 2.12,
4.24 A dc (0.001 A)

Continuous

0.707 A (0.0001 A), 1.41
A, 2.83 A dc (0.001 A)

450 Va Source

F6150 Ranges (Resolution)

ac current
Transient

2.25, 4.5, 9.0 A rms
(0.001 A)

Continuous

1.5, 3.0, 6.0 A rms
(0.001 A)

Dc current
Transient

1.59 (0.0001 A), 3.18,
6.36 A dc (0.001 A)

Continuous

1.06, 2.12, 4.24 A dc
(0.001 A)

®