General Specifications

interfaces

Ethernet or USB control to PC

line power Supply

105–132 V or 210–264 V, 47–63 Hz

eMc emissions

FCC 47 CFR Part 15 Class A (USA)
EN55011:1998/A1:1999/A2:2002 Group1 Class A ISM(EU)
AS/NZS CISPR 11:2004 Class A ISM (Australia)
ICES-001 Issue 3 ISM (Canada)

eMc immunity

EN 61000-6-2:2005; IEC 61000-4-2/3/4/5/6/11

Safety

EN 61010-1; UL 61010-1; CSA 27.2 # 61010-1

environmental

IEC 60068-2-2 Dry Heat (+ 85°C storage; + 50°C Operating)
IEC 60068-2-1 Cold (- 50°C storage; 0°C operating)
IEC 60068-2-30 Damp Heat (+55°C, 6 cycles, 95% humidity)
NEMA Enclosure Rating Type 1
IEC Enclosure Rating IP20

Mechanical

IEC 60068-2-27 Shock (15g/11ms, half sine)
IEC 60068-2-6 Vibration (10-150 Hz, 20 m/s

2

)

IEC 60068-2-6 Drop test

iec61850 communication

Certified by KEMA as being compliant with IEC61850 protocol
(IEC 61850-7-2 and 8-1)

humidity

Up to 95% relative humidity non-condensing

MKT-SL-F6150TS-03/10

Doble is certified iSo 9001:2000

Doble is an eSco Technologies company

additional external F6150 options
described in other Doble product
brochures:

F6010 controller

F6080 Field calibration Unit

F6300 high-power

current amplifier

F6050 Universal Time

Synchronizer

GpS accuracy

With F6895 (Antenna and Receiver):
+/-50 nanoseconds
With F6050:
+/-10 microseconds

enclosure

High-impact, molded, flame-retardant ABS
– meets National Safe Transit Association
testing specification No. 1A for immunity
to severe shock and vibration

Dimensions

15 x 9.5 x 18 inches
38 x 24 x 45.7 cm

Weight

37.5 lb 17.05 kg
(with front cover and
carrying strap)

Quality assurance Management System

Third-party certification to ISO 9001:2000

calibration

Certification traceable to N.I.S.T. standards

electrostatic Discharge immunity

IEC 801-2 I.E.C. performance level 1
@ 10 kV: normal performance within
specifications. I.E.C. performance level 2
@ 20 kV: no permanent damage.

Surge Withstand capability

ANSI/IEEE C37.90. The simulator functions
as a source during surge withstand
capability tests, when the ANSI/IEEE
specified isolating circuit is interposed
between the simulator and the test relay.