Digital multimeter specifications

• Accuracy is given as ± (% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity < 80 RH.

• AC V specifications are AC coupled, true RMS and are valid from 5% to 100% of range.

Maximum reading

10,000 counts with automatic polarity indication

Voltage

CAT II 1000 V or CAT III 600 V

Function

Range

Resolution

Accuracy

Input impedance

(nominal)

Test current

DCV

1000.0 mV

0.1 mV

0.09% + 5

11.11 MΩ

10.000 V

0.001 V

0.09% + 2

10.10 MΩ

100.00 V

0.01 V

10.01 MΩ

1000.0 V

2

0.1 V

0.15% + 5

ACV

1000.0 mV

0.1 mV

1% + 5 (40 to 500 Hz)

10.00 MΩ

2% + 5 (500 Hz to 1 kHz)

10.000 V
100.00 V

0.001 V

0.01V

1% + 5 (40 to 500 Hz)

1% + 5 (500 Hz to 1 kHz)

2% + 5 (1 to 2 kHz)

1000.0 V

2

0.1 V

1% + 5 (40 to 500 Hz)

1% + 5 (500 Hz to 1 kHz)

ACV + DCV

1000.0 mV

0.1 mV

1.1% + 10 (40 to 500 Hz)

10.00 MΩ

2.1% + 10 (500 Hz to 1 kHz)

10.000 V
100.00 V

0.001 V

0.01 V

1.1% + 7 (40 to 500 Hz)

1.1% + 7 (500 Hz to 1 kHz)

2% + 5 (1 to 2 kHz)

1000.00 V

2

0.1 V

1.2% + 10 (40 to 500 Hz)

1.2% + 10 (500 Hz to 1 kHz)

Diode

3

1 V

0.001 V

0.3% + 2

~0.5 mA

Beeper < ~50 mV, Single tone for normal forward-biased diode or semiconductor junction of

0.3 V ≤ reading ≤ 0.8 V

8

Instant continuity

3

Continuous beep when resistance < 10 Ω

8

Resistance

1000.00 Ω

4

0.1 Ω

0.3% + 3

0.5 mA

10.000 kΩ

4

0.001 kΩ

50 µA

100.00 kΩ

0.01 kΩ

4.91 µA

1000.0 kΩ

0.1 kΩ

447 nA

10.000 MΩ

0.001 MΩ

0.8% + 3

112 nA

100.00 MΩ

5

0.01 MΩ

1.5% + 3

112 nA

Capacitance

1000.0 nF

0.1 nF

1.2% + 4

6

10.000 μF

0.001 μF

100.00 μF

0.01 μF

1000.0 μF

0.1 μF

2% + 4

6

10.000 mF

0.001 mF