Trigger modes, Inputs and outputs – Atec Agilent-81100 Series User Manual

Page 7

Advertising
background image

Data Sheet 81100 Family of Pulse Pattern Generators

Pattern mode

Pattern length: 16 kbit/channel and
strobe output.

Output format: RZ (return to zero), NRZ
(non-return to zero), DNRZ (delayed
non-return to zero).

Random pattern:
PRBS 2 ^ (n - 1) n = 7,8,...,14.

Trigger modes

Continuous: Continuous pulses, double
pulses, bursts (single or double pulses)
or patterns.

External triggered: Each active input
transition (rising, falling or both)
generates a single or double pulse,
burst or pattern.

External gated: The active input level
(high or low) enables pulses, double
pulses, bursts or patterns. The last
single/double pulse, burst or pattern
is always completed.

External width: The pulse shape can be
recovered. Period and width of an external
input signal is maintained. Delay, levels
and transitions can be set.

Manual: Simulates an external input
signal.

Internal triggered: Internal PLL replaces
an external trigger source. Pulses, double
pulses, bursts or patterns can be set.

Strobe output and trigger output

Strobe output: User-defined, 16 kbit
pattern (NRZ) when in pattern mode.

Trigger format: One pulse per period with
50% duty cycle typical. External mode:
1.5 ns typ. for Agilent 81110A. 5.9 ns typ.
for Agilent 81104A.

Level: TTL or ECL selectable.

Output impedance: 50 Ω typical.

Max. external voltage: - 2 V/+7 V.

Transition times: 1.0 ns typical for TTL,
600 ps typical for ECL.

Inputs and Outputs

Clock input/PLL reference and
external input

PLL reference: (BNC connector at rear
panel). The internal PLL is locked to an
external 5 MHz or 10 MHz reference
frequency.

Clock input: (BNC connector at rear
panel). The output period is determined
by the signal at CLK input.

Ext. input: Used for trigger, gate or
external width.

Input impedance: 50 Ω/10 kΩ selectable.

Threshold: - 10 V to + 10 V.

Max. input voltage: ± 15 Vpp.

Sensitivity: ≤ 300 mVpp typical.

Transitions: < 100 ns.

Frequency: dc to max. frequency
of output module.

Min. pulse width: 1.5 ns (as width of
output module in external width mode).

7

Typical delay (Agilent 81110A with Agilent 81111A output module)

1

Instrument mode

From

To

Typ. value

External width

Ext. input

Strobe/trigger out
Output 1/output 2

8.5 ns
19.5 ns

All other modes

Ext. input/clk input

Strobe/trigger out
Output 1/output 2

12.0 ns
26.0 ns

Strobe/trigger out

Output 1/output 2

14.0 ns

1. Subtract 4 ns from the typ. delay value when referring to OUTPUT 1 / 2 for the Agilent 81112A output module and add 1 ns when referring to

OUTPUT 1 / 2 for the Agilent 81104A with the Agilent 81105A output module.

Advertising