Atec Kaelus-IQA Series User Manual

Iqa series, Portable passive intermodulation analyzer, Technical specifications

Advertising
background image

ADVANTAGE

Measurement method

Reverse (reflected) PIM, 3rd, 5th, 7th, 9th and 11th order

Residual PIM

< -115dBm/-158dBc max (<-125dBm/-168dBc typ) (x2 @ 20W)

User interface ports

3x USB, x1 LAN, 1x RF output (7-16 DIN female), 1x monitor port (N female)

Display

8.4in (213mm) touch screen display

Transmit frequencies

See model table

Frequency increment

50 kHz

Frequency accuracy

± 5ppm (max), aging ± 1ppm (max) after first year

Power per tone (adjustable)

2x 2 to 20W (+33 to +43dBm)

Power accuracy (per tone)

± 0.5dB (max)

- Rugged, reliable construction suitable for field use

- Fully configurable frequencies, powers and IM products

- Integrated polycarbonate transit case

- Simple to operate touch screen interface

- Range to Fault (RTF) enabled

- Spectrum monitor, frequency sweep and time trace modes

© 2012 Kaelus. All Rights Reserved.

www.kaelus.com

|1|

iQA Series

Portable Passive Intermodulation Analyzer

Passive Intermodulation (PIM) Analyzer,

Range to Fault (RTF) enabled

TECHNICAL SPECIFICATIONS |

SYSTEM

PRODUCT FEATURES

TRANSMITTER

Receive band (50kHz steps)

See model table

Measurement noise floor

< -128dBm

Measurement range

-50dBm to -128dBm

RECEIVER

The iQA series Passive Intermodulation (PIM) analyzer is a feature rich, high power

PIM test solution. This field proven analyzer enables network operators to improve

site performance by finding and eliminating sources of passive intermodulation at

the cell site. The design includes an integrated panel PC with intuitive touch screen

interface for performing tests and generating site reports.

This version of the iQA ships from the factory enabled to support Range to Fault

(RTF) technology: with the purchase of an optional RTF module, operators are able to

activate RTF mode within the iQA user software to accurately measure the distance

to return loss faults as well as the distance to PIM faults at the cell site.

RTF module sold separately.

Advertising