Atec Fluke-789 User Manual

Fluke 789 processmeter, Technical data ne w, Double your power

Advertising
background image

Technical Data

Ne

w

Fluke 789

ProcessMeter

1000V

CAT III

Designed and
Conforms to

IEC 1010-1

LISTED

950 Z

R

N10140

These 787 features are also included in the 789

DMM designed to meet 1000 volt IEC 1010
CAT III standards

Precision 1000 V, 440 mA True-rms digital
multimeter

Frequency measurement to 20 kHz

Min/Max/Average/Hold/Relative modes

Diode Test and Continuity Beeper

Simultaneous mA and % of scale readout

20 mA dc current source / loop calibrator /
simulator

Manual Step (100 %, 25 %, Coarse, Fine) plus
Auto Step and Auto Ramp

Externally accessible battery for easy battery
changes

Key new features of the Fluke 789

24 V Loop power supply

HART mode setting with loop power
(adds 250 ohm resistor)

100 % larger dual display

1200 ohm drive capability on mA source

Enhanced backlight with two brightness
settings

0-100 % mA Span Check buttons to toggle
between 4 and 20 mA

Infrared I/O serial port compatible with
FlukeView

®

Forms Software Version 2.1

(available Feb. 2003)

Externally accessible fuses for easy replacement

Double your power.

The Fluke 787 ProcessMeter was the
first tool to combine a loop calibrator
with a DMM to give process techni-
cians double the power in one tool.
Now it’s even better – the ultimate
loop calibration multimeter – the
Fluke 789 ProcessMeter.

The 789 has a display that’s not

only twice as large, but also twice as
bright with two levels of backlighting.
And with its built-in, selectable
250 ohm HART

®

resistor, it eliminates

the need to carry a separate resistor
with you.

Now process technicians can do a

lot more while carrying a lot less.

Advertising