Atec Fluke-Norma-4000-5000 Series User Manual

Technical data, High precision power analyzers, Fluke norma series power analyzers at a glance

Advertising
background image

Fluke Norma 4000/5000

High Precision Power Analyzers

Reliable, highly accurate

measurements for the test &

development of power electronics

Compact Fluke Norma Series power analyzers

include the latest power measurement

technology to assist engineers working with

motors, inverters, lighting, power supplies,

transformers and automotive components in

making their products more efficient.

Based on a patented high-bandwidth

architecture, Fluke Norma Series power analyzers

deliver precise measurements of single or three-

phase current and voltage, harmonics analysis,

Fast Fourier Transformation (FFT) analysis, as well

as calculations of power and other derived

values. They provide class-leading accuracy and

common mode rejection for any waveform,

frequency, or phase shift.

Technical Data

ENEN

Fluke Norma 4000:

Ideal for field testing, the Fluke Norma

4000 power analyzer offers easy and

straight-forward operation. Features

include: 1 to 3 power phases, 5.7” / 144

mm color display, harmonic analysis, FFT

analysis, scope mode, vector diagram

display, recorder function, Fluke

NormaView PC software, and 4 MB RAM

data memory.

Fluke Norma 5000:

Providing the highest bandwidth on the

market, the Fluke Norma 5000 power

analyzer is the ideal test and analysis tool

for the development of frequency

converters and lighting equipment.

Features include: 1 to 6 power phases,

optional internal printer, and all of the

features and functionality of the Fluke

Norma 4000 power analyzer described

above.

Fluke Norma 4000

Fluke Norma 5000

Number of Phases

1 or 3

3, 4 or 6

Bandwidth

dc to 3 MHz or dc to 10 MHz depending on input

module

Basic Accuracy

0.2%, 0.1% or 0.03% depending on input

modules

Sampling Rate

0.33 MHz or 1 MHz depending on input modules

Voltage Input Range

0.3 to 1000 V

Current Input Range (direct, not via shunt)

0.03 mA – 20 A depending on input module

Display

Color, 5.7“ / 144 mm - 320 x 240 pixel

Memory for Configurations

4 MB

Memory for Settings

Standard

Fast Fourier Transformation (FFT)

To the 40

th

harmonic

RS232 Interface

Standard

PI1 Process Interface

(8 analog / impulse inputs and 4 analog

outputs)

Optional

IEEE 488/GPIB Interface

Optional

Fluke NormaView PC Software (for data

download, analysis & report writing)

Standard

Fluke Norma Series power analyzers

at a glance

99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-571-8431

Visit us at www.TestEquipmentDepot.com

Advertising