ENEN

Automotive – Detailed analysis of all electrical and

mechanical components installed in modern cars for

developing strategies that help reduce fuel

consumption or the increase the range of electric

vehicles. Synchronous electrical input and

mechanical output measurements provide complete

data on the efficiency and losses of individual

components as well as the whole drive system.

Switching power supplies and UPS – Very wide

bandwidth enables detailed and accurate power

measurements in the switching link of switching

power supplies. Unique coaxial shunt technology

delivers precision results in high frequencies of

several 100 kHz.

Charge pumps/boost converters – Wide

measurement bandwidth combined with wide

dynamic range enable precise measurements of

charge pumps with very high switching frequency

in the link circuit.

Current transducers – Detect very small phase

shift errors between the various current and voltage

channels for support the calibration of current

transducers.

tan

δ (dissipation factor) measurement – Measure

power at very small power factors and calculate tan

δ from voltage and current at very low loss angles.

Calibration and test laboratories – High

measurement accuracy enables use as a standard

for power calibration and for the certification of

voltage, current, power and distortion.

Fast Fourier Transformation (FFT)

Calculation of harmonics with graphical

representation. Up to 3 harmonic

spectrums are displayed simultaneously.

Measured values: U, I, & P per phase.

Order: 1

st

to 40

th

harmonics, maximum

half sample frequency.

Digital Oscilloscope (DSO)

Simultaneous display of up to 3

measured values at sample level. Quick

view of waveform and distortion.

Integration function (Energy)

Simultaneous display of up to 6

configurable numeric values. Start/Stop

conditions and positive negative

direction available.

Vector display

Vector display of the fundamental for up

to 6 signals. For easy testing of the right

connection of the instrument and quick

overview of the phase angle of each

signal.

Recorder function

Display of average values over time for

trend determination.

RAM data memory

Storing of sample and average values;

setting of start and stop conditions.

From the RAM approximately 4 MB are

available for the storage of measured

values. The memory can be expanded

up to 128 MB.

Configuration

Set up the analyzer to measure and

display data in the format required.

Basic Functions

3 Fluke Corporation Analyseurs de puissance de la Fluke Norma 4000/5000

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com