Atec Kikusui-PLZ-4W Series User Manual

Page 10

Advertising
background image

10

P L Z - 4 W S E R I E S

[Meters]

*1

Displays the product of the

voltmeter reading and ammeter
reading.

*2

In a mode other the CP mode

*3

In CP mode

[Switching mode]

*1

The minimum time width is 10

μs. Between 5 kHz and 20 kHz,
t h e m a x i mu m d u t y c y c l e i s
limited by the mini-mum time
width.

[Slew rate]

*1

In CC mode. The maximum slew

rate of each range is 1/10th the
value in CR mode.

*2

Time to reach from 10 % to 90 %

when the current is varied from 2
% to 100 % of the rated current.

Meters

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Voltmeter

Range

H, M

0.00 V – 150.00 V

L

0.000 V – 15.000 V

Accuracy

±(0.1 % of rdg + 0.1 % of f.s)

Ammeter

Range

H, M

0.000 A

– 33.000 A

0.000 A

– 66.000 A

0.00 A

– 200.00 A

0.000 A

– 33.000 A

0.00 A

– 132.00 A

L

0.00 A

– 330.00 mA

0.00 A

– 660.00 mA

0.0000 A

– 2.0000 A

0.00 A

– 330.00 mA

0.000 A

– 1.3200 A

Accuracy

±(0.2 % of rdg + 0.3 % of f.s)

Wattmeter

*

1

Range

H, M

0.00 W

– 165.00 W

0.00 W

– 330.00 W

0.0 W

– 1000.0 W

0.00 W

– 165.00 W

0.00 W

– 660.00 W

L

*

2

0.000 W

– 49.500 W

0.000 W

– 99.000 W

0.00 W

– 300.00 W

0.000 W

– 49.500 W

0.000 W

– 198.00 W

L

*

3

0.0000 W

– 1.6500 W

0.0000 W

– 3.3000 W

0.000 W

– 10.000 W

0.0000 W

– 1.6500 W

0.0000 W

– 6.6000 W

Switching mode

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Operation mode

CC and CR

Duty cycle setting

5 % – 95 %

*

1

, 0.1 % step

Selectable frequency range

1 Hz – 20 kHz

Frequency
resolution

1 Hz – 10 Hz

0.1 Hz

10 Hz – 100 Hz

1 Hz

100 Hz – 1 kHz

10 Hz

1 kHz – 20 kHz

100 Hz

Frequency accuracy of setting

±(0.5 % of set)

Slew rate

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Setting range

*

1

Range

H

2.5 mA/

μs

– 2.5 A/

μs

5 mA/

μs

– 5 A/

μs

16 mA/

μs

– 16 A/

μs

2.5 mA/

μs

– 2.5 A/

μs

10 mA/

μs

– 10 A/

μs

M

250

μA/μs

– 250 mA/

μs

500

μA/μs

– 500 mA/

μs

1.6 mA/

μs

– 1.6 A/

μs

250

μA/μs

– 250 mA/

μs

1 mA/

μs

– 1 A/

μs

L

25

μA/μs

– 25 mA/

μs

50

μA/μs

– 50 mA/

μs

160

μA/μs

– 160 mA/

μs

25

μA/μs

– 25 mA/

μs

100

μA/μs

– 100 mA/

μs

Resolution

See below.

Accuracy of setting

*

2

±(10 % of set + 5

μs)

Slew rate resolution

PLZ164W
PLZ164WA

Setting

25

μA/μs

– 250

μA/μs

250

μA/μs

– 2.5 mA/

μs

2.5 mA/

μs

– 25 mA/

μs

25 mA/

μs

– 250 mA/

μs

250 mA/

μs

– 2.5 A/

μs

Resolution

100 nA

1

μA

10

μA

100

μA

1 mA

PLZ334W

Setting

50

μA/μs

– 500

μA/μs

500

μA/μs

– 5 mA/

μs

5 mA/

μs

– 50 mA/

μs

50 mA/

μs

– 500 mA/

μs

500 mA/

μs

– 5 A/

μs

Resolution

200 nA

2

μA

20

μA

200

μA

2 mA

PLZ664WA

Setting

100

μA/μs

– 1 mA/

μs

1 mA/

μs

– 10 mA/

μs

10 mA/

μs

– 100 mA/

μs

100 mA/

μs

– 1 A/

μs

1 A/

μs

– 10 A/

μs

Resolution

400 nA

4

μA

40

μA

400

μA

4 mA

PLZ1004W

Setting

160

μA/μs

– 1.6 mA/

μs

1.6 mA/

μs

– 16 mA/

μs

16 mA/

μs

– 160 mA/

μs

160 mA/

μs

– 1.6 A/

μs

1.6 A/

μs

– 16 A/

μs

Resolution

600 nA

6

μA

60

μA

600

μA

6 mA

Soft start

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Operation mode

CC and CR

Selectable time range

1, 2, 5, 10, 20, 50, 100, or 200 ms

Time accuracy

±(30 % of set +100

μs)

Remote sensing

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Voltage that can be compensated

2 V for a single line

Protection function

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Overvoltage protection (OVP)

Turns off the load at 110 % of the rated voltage

Overcurrent protection (OCP)

0.03 A – 36.3 A

0.06 A – 72.6 A

0.2 A – 220 A

0.03 A – 36.3 A 0.13 A – 145.2 A

Or 110 % of the maximum current of each range

Overpower protection (OPP)

0.1 W – 181.5 W

0.3 W – 363 W

1 W – 1 100 W

0.1 W – 181.5 W

0.6 W – 726 W

Or 110 % of the maximum power of each range

Load off or limit selectable

Overheat protection (OHP)

Turns off the load when the heat sink temperature reaches 95 °C

Undervoltage protection (UVP)

Turns off the load when detected.

Can be set in the range of 0 V to 150 V or Off.

Reverse connection protection (REV)

By diode and fuse. Turns off the load when an alarm occurs.