Support of 0-v input and high-speed response, Six operation modes, Support of 0-v input – Atec Kikusui-PLZ-4W Series User Manual

Page 5: Variable slew rate, High precision and high resolution, Basic performance and operations, Equivalent circuit and operation in each mode, Plz164w operating range and setting resolution

Advertising
background image

5

P L Z - 4 W S E R I E S

Six operation modes

The system can operate in six modes - constant current,
constant resistance, constant voltage, constant power,
constant current + constant voltage, and constant resistance
+ constant voltage.

Support of 0-V input

PLZ164WA and PLZ664WA are 0-V input operating voltage
models. This feature is indispensable for testing single-cell
fuel cells. The continuing trend toward lower power
consumption and semiconductor process miniaturization is
driving semiconductor devices to operate on increasingly
lower voltages. These models are suitable for evaluating
such power supplies.

* This product detects a ‘no-input’ state when the input voltage is below about 0.3 V

and when the input current is below about 1% of the range rating. Therefore, if the
input voltage is raised gradually from 0 V, no current flows until the input voltage
exceeds 0.3 V. If a current exceeding 1% of the range rating flows, it is possible to
have a current flow at less than 0.3 V.

* PLZ164WA and PLZ664WA have bias supplies inside their chassis. In the case of

a power supply in which a diode is arranged in the direction from the minus output
to the plus output, such as a switching power supply, if the output of the power
supply of the device under test is turned off with this system’s load on, the current
flows from the bias supply to the diode, generating a reverse connection alarm.

Variable slew rate

The slew rate determines the slope of change in the current
when the set current needs to change sharply as in a
transient response test. This system lets you set the current
change rate per unit time as appropriate for the selected
current range.

* Adequate slew rate performance is guaranteed as long as the change in the current

remains within the 2%-to-100% range of the rating. The maximum rise time is
limited to 10

μs. If the change in the current is small, the slew rate value may not

be stored for the reason stated above.

High precision and high resolution

The built-in three-range configuration provides both wide
dynamic range and high precision. The voltmeter, ammeter
and wattmeter functions that display values using up to five
digits each and a minimum setting resolution of 10

μA (for

the PLZ164W/164WA L range) are implemented.

• Shift in the current

waveform with the
change in the
slew rate

Equivalent circuit and operation in each mode

Support of 0-V Input and High-Speed Response

Basic Performance and Operations

PLZ164W operating range and setting resolution

Operating range

Setting resolution

Constant

current mode

H range

M range

L range

0 A to 33 A

0 A to 3.3 A

0 A to 330 mA

1 mA

0.1 mA

0.01 mA

Constant

resistance

mode*

H range

M range

L range

22 S to 400

μS

2.2 S to 40

μS

0.22 S to 4

μS

400

μS

40

μS

4

μS

Constant

voltage mode

H range

L range

1.5 V to 150 V

1.5 V to 15 V

10 mV

1 mV

Constant

power mode

H range

M range

L range

16.5 W to 165 W

1.65 W to 16.5 W

0.165 W to 1.65 W

10 mW

1 mW

0.1 mW

* Conductance [S] = Input current [A]/Input voltage [V] = 1/Resistance

[

Ω]

PLZ-4W Series

Electronic Load

I

V

Constant Voltage

power supply

Current is constant

even when the voltage

changes

Current I

Voltage

V]

0

V

1

CC setting value

Voltage

V]

Current I

Voltage

V]

Current I

Voltage

V]

Current I

Voltage

V]

Current I

Voltage

V]

Current I

I

V

PLZ-4W Series

Electronic Load

Constant voltage

power supply

Resistance (V/I) is constant

even when the voltage and

current vary

0

V1

V

2

V

1

I

1

I

2

V

2

V

1

I

1

I

2

=

=

R

Constant voltage

power supply

PLZ-4W Series

Electronic Load

Constant voltage

power supply

PLZ-4W Series

Electronic Load

PLZ-4W Series

Electronic Load

PLZ-4W Series

Electronic Load

I

V

0

Power (current×voltage) is constant

even when the current and voltage vary

V

1

V

2

V

1

I

1

I

2

V

2

V

1

I

1

I

2

=

=

P

Rated maximum

current value

I

V

R

1

Voltage is constant even

when the current varies

V

1

0

Battery

I

V

R

1

CV operation

Voltage is constant even

when the current varies

Current is constant

even when the

voltage varies

V

M

 

0

CC operation

CC setting value

CV

Setting

value

Battery

Setting

value

I

V

V

M

R

1

0

CV

CV operation

Voltage is constant even

when the current varies

CR operation

Resistance (V/I) is constant

even when the voltage and

current vary

●Constant current mode(CC)

●Constant resistance mode(CR)

●Constant voltage mode(CV)

●Constant power mode(CP)

●Constant current+constant voltage mode(CC+CV)

●Constant resistance+constant voltage mode(CR+CV)

Advertising