I/q modulation, I/q modulator, External wideband i/q – Atec Rohde-Schwarz-SMJ100A User Manual

Page 13

Advertising
background image

Version 05.00, December 2007

R&S

®

SMJ100A Vector Signal Generator

13

I/Q modulation

I/Q modulator

Operating modes

external wideband I/Q,
internal baseband I/Q

I offset, Q offset

setting range

−10 % to +10 %

resolution 0.01

%

gain imbalance

setting range

−1.0 dB to +1.0 dB

resolution 0.001

dB

quadrature offset

setting range

−10° to +10°

I/Q impairments

resolution 0.01°

I/Q swap

I and Q signals swapped

ON/OFF

External wideband I/Q

input impedance

50

Ω

VSWR up to 50 MHz

<1.2

input voltage for full-scale input

q

2

2

i

+

= 0.5 V

V

V

I/Q inputs

minimum input voltage for ALC state ON

0.1 V

Modulation frequency range

I/Q wideband ON

100 MHz

Carrier leakage

without input signal, referenced to full-
scale input

4

<

−55 dBc, typ. <−65 dBc

measured with 16QAM, root cosine filter,
α = 0.5, symbol rate 10 kHz

rms value

f

≤ 200 MHz

<0.3 %

f > 200 MHz

<(0.2 % + 0.1 % × f/GHz)

peak value

f

≤ 200 MHz

<0.6 %

Error vector

f > 200 MHz

<(0.4 % + 0.2 % × f/GHz)

Delta / dB

5

4

3

2

1

0

–1

– 2

– 3

– 4

– 5

Frequency offset from carrier / MHz

– 100

100

0

60

– 20

– 60

20

40

80

– 80

– 40

RF 850 MHz
RF 1900 MHz
RF 2200 MHz

Measured frequency response of external wideband I/Q modulation

4

Value applies after 1 hour warm-up and recalibration for 4 hours of operation and temperature variations of less than +5 °C.