Digital baseband output (R&S

®

SMJ-B18 option)

The R&S

®

SMJ-B18 option makes digital I/Q signals available on the rear panel of the instrument. The digital I/Q output can be used

for the lossless connection of the R&S

®

SMJ100A to the digital I/Q input of other Rohde & Schwarz instruments (e.g. R&S

®

AMU200A

baseband signal generator and fading simulator).

Interface standard

in line with Rohde & Schwarz TVR290,
I/Q data and control signals, data and
interface clock

level

LVDS

connector

26-pin

MDR

data rate

30 MHz to 100 MHz with 1 MHz resolution,
81.6 MHz

I/Q sample rate

With source ‘user-defined’, the sample rate must be entered via the parameter ‘sample
rate’, no I/Q data clock being necessary. With source ‘digital I/Q out’ or ‘digital I/Q in’,
the sample rate will be estimated on the basis of the applied I/Q data clock.

source

user-defined,

digital I/Q out, digital I/Q in

sample rate

400 Hz to 100 MHz

max. sample rate limited by actual
interface data rate

resolution (user-defined)

0.001 Hz

frequency uncertainty (user-defined)

< 5 × 10

–14

I/Q data

resolution

18 bit

logic format

two's complement

physical signal level

setting range

0 to –60 dBFS

resolution

0.01

dBFS

bandwidth

sample rate = 100 MHz (no
interpolation, user-defined)


40 MHz

sample rate <100 MHz (interpolation)

0.31 × sample rate

Control signals

markers

4

data valid

valid samples marked in data stream

Advertising