22

Rohde & Schwarz

R&S

®

SMU200A Vector Signal Generator

resolution

18 bit

logic format

two’s complement

physical signal level

setting range

0 to –60 dBFS

resolution 0.01

dBFS

bandwidth

sample rate = 100 MHz
(no interpolation, user-defined)

40 MHz

I/Q data

sample rate < 100 MHz (interpolation)

0.31 × sample rate

markers 4

Control signals

data valid

valid samples marked in data stream

Baseband input (analog/digital) (R&S

®

SMU-B17 option)

At least one R&S

®

SMU-B13 baseband main module and at least one R&S

®

SMU-B9/-B10/-B11 I/Q baseband generator must be

installed. The R&S

®

SMU-B17 option makes it possible to feed external analog or digital signals to the baseband section of the

R&S

®

SMU200A. The frequency of the signals can be shifted, and the signals can be added to the internally generated signal with

settable level ratio. If the R&S

®

SMU200A is equipped with a fading simulator, the input signals can also be faded.

Mode

see also simultaneous modulation

analog input,
digital input

peak level

setting range

–10 dB to 0 dB referenced to full scale

resolution 0.01

dB

crest factor

setting range

0 dB to 30 dB

resolution 0.01

dB

Input level

The adjust level function automatically determines the peak level and crest factor of the
input signal.
The frequency offset can be used to shift the center frequency of the input signal in the
baseband. The restrictions caused by the modulation bandwidth apply.
setting range

−40 MHz to +40 MHz

resolution 0.01

Hz

Frequency offset

frequency accuracy

< 5 Ч 10

− 10 Ч frequency offset +

reference frequency error

I/Q swap

I and Q signals swapped

on/off

Analog I/Q inputs
All specifications apply to a peak level of 0 dB.

input impedance

50

VSWR up to 30 MHz

< 1.1, 1.03 (typ.)

I/Q inputs

input voltage for full-scale input

q

2

2

i

+

= 0.5 V

V

V

carrier leakage I, Q

setting range

−10 % to +10 %

resolution 0.01

%

I

≠ Q (imbalance)

setting range

−3 dB to +3 dB

resolution 0.001

dB

I/Q skew

setting range

–1 ns to +1 ns

I/Q impairment

resolution 1

ps

sample rate

100 MHz

A/D converter

resolution 14

bit

with amplitude and group delay correction
bandwidth, roll-off to –0.1 dB

30 MHz

Aliasing filter

stopband rejection, f

≥ 70 MHz

80 dB (typ.)

I/Q wideband: on, optimize internal I/Q impairments for RF output: on

up to 10 MHz

0.2 dB (typ.)

RF frequency response for entire
instrument in modulation bandwidth

up to 30 MHz

0.4 dB (typ.)