Version 08.00, January 2012

Rohde & Schwarz

R&S

®

SMU200A Vector Signal Generator

27

The frequency offset can be used to shift the center frequency of the modulation signal
in the baseband. The restrictions caused by the modulation bandwidth apply.
setting range

−40 MHz to +40 MHz

resolution 0.01

Hz

Frequency offset

frequency uncertainty

< 5 Ч 10

− 10 Ч frequency offset +

reference frequency error

internal
All 0, All 1

PRBS

sequence length

9, 11, 15, 16, 20, 21, 23

pattern

length

1 bit to 64 bit

data lists

R&S

®

SMU-B9 output memory

8 bit to 4 Gbit

R&S

®

SMU-B10 output memory

8 bit to 2 Gbit

R&S

®

SMU-B11 output memory

8 bit to 512 Mbit

nonvolatile memory

hard disk

external
In the case of serial transmission, the symbol strobe marks the LSB of the symbol, and
the maximum symbol rate is limited by the data rate of the interface.
serial

word width

1 bit to 10 bit

bit rate

max. 60 MHz

parallel

word width

1 bit to 10 bit

Data sources

symbol rate

max. 25 MHz

In internal clock mode, a trigger event restarts the clock generation. The clock phase is
then synchronous with the trigger (with a certain timing uncertainty).
In external clock mode, the trigger event is synchronized to the symbol clock.
operating mode

internal, external

modes

auto, retrig, armed auto, armed retrig

setting uncertainty for clock phase related
to trigger in internal clock mode

< 18 ns

external trigger delay

setting range

0 sample to (2

16

– 1) sample

resolution

internal clock mode

0.01 sample

external clock mode

1 sample

setting uncertainty

< 5 ns

external trigger inhibit

setting range

0 sample to (2

26

– 1) sample

resolution 1

sample

external trigger pulse width

> 15 ns

Triggering

external trigger frequency

< 0.02 × sample rate