The modular solution for 6 kv applications, Nsg 3060 – Atec Teseq-Schaffner-NSG3060 User Manual
Page 4
A d v a n c e d Te s t S o l u t i o n s f o r E M C
Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]
www.teseq.com
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS
NSG 3060
691-130B August 2009
Parameter
Value
Field:
1 to 1200 A/m (in 1 A/m steps)
Polarity:
positive / negative / alternate
Repetition time:
5 s to 10 min (in 1 s steps)
Impedance:
2 Ω
Coil factor
0.01 to 50.00
Test duration:
1 to 9’999 pulses; continuous
Phase synchronization:
asynchronous, synchronous 0 to 359º (in 1º steps)
Field:
1 to max. 40 A/m (in 1 A/m steps)
Frequency:
50/60 Hz
Coil factor:
0.01 to 99.99
Test duration:
1 to 9’999 pulses, continuous
Pulsed magnetic field in conjunction with INA 753 and INA 701 or 702
conforms to IEC/EN 61000-4-9
Power magnetic field in conjunction with MFO 6501 / MFO 6502 and INA 70x
conforms to IEC/EN 61000-4-8