Radiated immunity test system 6 GHz

its 6006

82-254005 E02 March 2011

Generator (continued)

Pulse modulation
Modulation frequency range: 1 Hz – 2 kHz
Frequency resolution:

1 Hz

Duty cycle:

10% to 90%

External modulation
Level:

1 Vpp to get 100% AM, 1 Hz – 10 kHz

Analog ports

Front panel
Monitoring input analog:

BNC socket, 0-24 V Ri=15 kΩ, 6 mV resolution

User port:

D-Sub 15 pole

PIN 15:

+12 V / max. 200 mA

PIN 14:

-12 V / max. 200 mA

PIN 13:

+5 V / max. 200 mA

PIN 5 and 10:

GND

Back panel
Generator outputs:

4x N sockets 50 Ω, 80 MHz – 6 GHz

Interlock outputs:

4x BNC sockets

External modulation input:

BNC socket, impedance >10 kΩ

10 MHz reference output:

BNC socket, approx. 0 dBm / 50 Ω

RF Switch network:

Relay type 2x SPDT, N sockets 50 Ω

Power up to 100 MHz:

1500 W

Power up to 400 MHz:

800 W

Power up to 1 GHz:

500 W

Power up to 3 GHz:

300 W

Power up to 6 GHz:

200 W

Digital ports

Front panel
Power meter inputs 1 to 3:

for connecting up to 3 Teseq PMR 6006

Monitoring digital input 1 and 2: BNC socket, 0-24 V via optical coupler Ri=1.5 kΩ, switching threshold

approx. 2-3 V