General specifications, Operating instructions – atwood Air Conditioners (13500, 15000) User Manual

Page 11

Advertising
background image

Air – Conditioner
Height - 12.8 inch (325mm)
Width – 26.6 inch (675mm)
Length - 38.4 inch ( 975mm)
Weight – 99 lb (45kg)
Air Discharge Plenum
Height - 2.6 inch (65mm)
Width - 21.0 inch (535mm)
Length - 21.8 inch (555mm)
Weight – 1.1 lb ( 2.4kg)

GENERAL SPECIFICATIONS

AC Description

Model Number

13.5K Non-Ducted AC – White

AC-1351W

13.5K Non-Ducted AC – Black

AC-1351B

15K Non-Ducted AC – White

AC-1501W

15K Non-Ducted AC – Black

AC-1501B

Model 13500

Model 15000

Electrical Rating:

115V, 60Hz

115V, 60Hz

Electrical Rating:

13,500 BTU/Hr

15,000 BTU/Hr

Nominal Heating Capacity:

n/a

15,000 BTU/Hr

F.L.A. Cooling:

12.5 A

13.0 A

F.L.A. Heating:

n/a

13.0 A

Locked Rotor Amps:

63 A

63 A

Refrigerant:

R410A

R410A

Refrigerant:

18 Oz (510 g)

24 Oz (670 g)

Total Installed Weight:

106 lb (48 Kg)

108 lb (49Kg)

OPERATING INSTRUCTIONS

- Turn the unit on by pressing the ON/OFF button once.
- Press the MODE button to cycle through options Cool,
Dry, Heat and Fan.
COOLING
- Cycle mode button to highlight COOL.
- You may select High, Med, Low, or Auto fan speeds by
pressing the fan button. It is recommenced that you choose
Auto.
- Now select the desired room temperature (herein referred to
as SETPOINT) by pressing the TEMP up or down keys, the
readout will flash the set point temperature. Keep pressing
the button until it flashes your desired set point. In approx. 5
seconds the display will resume reading the actual room
temperature. The compressor will have a delayed start
usually 3 minutes before unit starts to cool.
Note: Any interruption to the power supply will cause the
unit to delay compressor start up.
- For simply re-circulating air, choose the FAN mode.
Choose any of the three fan speeds by pressing FAN button.
Note: Temperature button is invalid in Fan only mode.
HEAT

(model 15000 only)

- To heat, press MODE button to highlight HEAT.
- Select desired set point temperature by pressing TEMP buttons up or down. It is recommended that AUTO
fan speed by selected.
- After the delay, the compressor will start. Usually the fan will stop and will not re-energize until the heat
exchanger has warmed and then the fan will start to blow warm air.

Advertising