Operation, Pre-delivery preparation, Caution – atwood Levelegs System User Manual

Page 2: Warning

Advertising
background image

2

MOTOR HOME SIGNAL WIRE HARNESS

1. Connect the motor home signal wire harness (

FIG

3-I) to the con-

troller (

FIG

3-K).

2. Motor home signal wire harness to be configured as follows (

FIG

8):

ITEM

DESCRIPTION

QTY

A

43025

Molex

®

Micro-fit 3.0,8 circuit receptacle

1

B

43030

Molex

®

Micro-fit 3.0 female tin terminal

4

C

Unshielded 20 AWG multiconductor cable

1

Pin Requirements - (

FIG

8)

CONNECTOR PIN

DESCRIPTION

(

REFERENCE

)

FIGURE

COLOR

P1

Park Brake

D

white

P2

Transmission

E

green

P3

N/A

F

N/A

P4

N/A

G

N/A

P5

Foot Brake

H

red

P6

N/A

I

N/A

P7

Ignition*

J

black

P8

N/A

K

N/A

* Install with a 3 AMP in-line fuse to chassis ignition wire.

3. Crimp the contacts with the approved Molex

®

die.

4. Crimped contacts must withstand a minimum nine (9) pound pull force.
5. Terminate the sleeve of multi-conduit cable to within 1˝ of connector

(

FIG

8-L)

6. Length of harness “as required” to easily connect control pad to

controller (

FIG

8-M).

POWER CONNECTIONS (FIG 3)

A - Driver Front Leveler

G - Yellow (+) Motor Gear Box Lead

B - Passenger Front Leveler

H - Control Pad Wire Harness

C - Driver Rear Leveler

I - Motor Home Signal Wire Harness

D - Passenger Rear Leveler

L - Female Connector (Delphi

®

)

E - 125 Resetable Circuit

M - Male Connector (Delphi

®

)

Breaker for 2 AWG

O - Air Bag Dump Valve (optional)

battery wire

P - Air Bag Fill Valve (optional)

F - Red (-) Motor Gear Box Lead R - Male connector (Deutsch

®

)

S - Female connector (Deutsch

®

)

Controller to Battery
1. Connect the controller to the chassis 12 VDC battery through the

manual reset circuit breaker or fuse (

FIG

3-E).

2. Connect the controller to the battery through 2 AWG wire (

FIG

3-N).

3. Terminate 2 AWG wire (

FIG

5-A)

power wire to controller through a

2 AWG 1/4” ID ring terminal (

FIG

5-B)

4. Attach ring terminal to controller with following components:

#10 conductive washer

FIG

5-C

#10 lock conductive washer

FIG

5-D

10-32 conductive nut

FIG

5-E

Note: Torque nut (

FIG

5-E) to 20-25 in/lbs.

Levelers to Controller
Controller must be connected to levelers through a wire harness
using 8 or 10 AWG wire.

Use 8 AWG wire for leveler rated above 10,000 lbs
or wire runs longer than 30 feet.

Use 10 AWG wire for levelers rated at or below 10,000 lbs
or wire runs shorter than 30 feet.

Leveler End (

FIG

6)

A. Use the following Delphi

®

or comparable components to terminate

both leads coming from the controller to lower motor connector
of the 7.5K or 10K levelers.

12065863

Connector

Male

FIG

6-A

12052172

Terminal

Male

FIG

6-B

12034170

Cable Seal

FIG

6-C

12059897

Secondary Lock

FIG

6-D

1. Strip wires (

FIG

6-F) back about 3/8˝ (

FIG

6-E).

2. Slide cable seal (

FIG

6-C) onto wire with neck of cable seal facing

stripped metal in wire.

3. Push cable seal forward to align neck of cable seal with edge of

insulation of stripped back wire end.

4. Put stripped wire into crimp wings closest to mating end of termi-

nal (

FIG

6-B) and neck of cable seal (around insulation) into sec-

ond set of wings furthest from mating end.

5. Crimp metal from wire to first set of wings.
6. Crimp cable seal neck (around insulation) to second set of wings.

Then snap secondary lock (

FIG

6-D) onto connector (

FIG

6-A).

7. Minimum of strength of core crimp without insulation crimp

should withstand a pull of 300 N (75 lbs).

8. Crimp dimensions:

CORE

:

2.4mm (.094˝) high

5.05mm (.20˝) wide

INSULATION

:

7.6mm (.30˝) high

7.4mm (.30˝) wide

NOTE

: Insert the terminals into the connectors with the flat bottoms

of the terminals oriented toward the connector locks.

B. To terminate 8 gage wire leads from the controller to 15K levelers

use the following components:

ITEM

PART

ATWOOD P

/

N

DEUTSCH P

/

N

S

connector, female

66627

DTHD04-1-8P

FIG

15-S

S2

contact pin

66635

0460-204-08

FIG

15-S2

R

connector, male

66636

DTHD06-1-8S

FIG

15-R

R2

contact socket

66634

0462-203-08

FIG

15-R2

Auto Position Controls
1. To terminate leads from the wire harness connected to the levelers

use the following components:

8 or 10 AWG wire

FIG

5-A

8 or 10 AWG, ring terminals

FIG

5-B

10 AWG

8 AWG

42816-0512 42516-0512

Connector

FIG

7-A

42815-0011 42815-0331

Terminal

FIG

7-B

2. Trim lead 5/16˝

FIG

7-C.

3. Pin connectors to match pins in Auto Position Control Board as

shown in

FIG

3.

4. Insert Molex

®

connector from wire harness into control board.

5. To address communication with the air suspension system, the con-

troller must have a single signal lead provided for “Air Dump”
(

FIG

3-O) and a single signal lead provided for “Air Fill” (

FIG

3-P).

PRE-DELIVERY PREPARATION

Wipe any excess fluid from the top of the foot before delivery.

OPERATION

BEFORE OPERATING THE LEVELERS

ƽ

CAUTION

PERSONAL INJURY

Stand clear of the vehicle.

Before operating the levelers, you must do the following:
1. Park the vehicle on a level site. Check for rocks, holes, or other

obstructions. Warn all persons to stand clear of vehicle.

2. For a motorhome,

• Put the vehicle transmission in

PARK

.

• Engage the vehicle

PARKING BRAKE

.

• Have the vehicle engine running.

3. Do not extend the slideouts until coach is level.

ƽ

WARNING

VEHICLE CAN TIP

Levelers must be on firm solid ground or surface prior to operation.
Soft/spongy ground may allow levelers to sink.

Area below and around leveler must be clear of obstructions.

Do not place blocks under the leveler for additional ground clearance.

LEVELERS ARE SHIPPED IN THE ERROR MODE STATE.

To take controls out of error mode state, complete a successful
ALL RETRACT (as defined in items 1-3) under TO RETRACT.

4. Put stripped yellow (+) wire end into contact pin (

FIG

15-52) and

crimp together. Crimp must withstand a minimum pull of 75 lbs.

5. Put stripped red (-) wire end into contact socket (

FIG

15-R2) and

crimp together. Crimp must withstand a minimum pull of 75 lbs.

6. Insert the contact pin (

FIG

15-S2) into the female housing (

FIG

15-S)

until it is secured. Then slip seal into housing.

7. Insert the contact socket (

FIG

15-R2) into the male housing (

FIG

15-

R) until it is secured. Then slip seal into housing.

Advertising