BVA Hydraulics PA1500L & PA3801L User Manual

Page 4

Advertising
background image

4

MAINTENANCE

Important: Use only a good quality hydraulic jack fluid. Never

use brake fluid, transmission fluid, turbine oil, motor oil, alcohol,

glycerin etc. Use of other than good quality hydraulic oil will

void warranty and damage the pump, hose, and application.

We recommend Mobil DTE 13M or equivalent.

1. Inspect hoses and connections daily. Replace damaged

components immediately with BVA Hydraulics replacement

parts only.

2. Tighten connections as needed. Use non-hardening pipe

thread compound when servicing connections.

3. Use only good quality hydraulic fluid. We recommend Mobil

DTE 13M or equivalent.

Adding Hydraulic Fluid

1. Depressurize and disconnect hydraulic hose from

application.

2. With pump in upright, horizontal position, remove the air

vent plug located on the top plate of the reservoir.

3. Use a small funnel to fill reservoir to within 3/4" (19mm) of

the opening.

4. Wipe up any spilled fluid and reinstall the air vent plug.

Changing Hydraulic Fluid

1. For best results, change fluid once a year.

2. Repeat step 2 on Adding Hydraulic Fluid, then pour used

fluid into a sealable container.

3. Dispose of fluid in accordance with local regulations.

4. Fill with a good quality hydraulic jack oil as recommended

above. Reinstall air vent plug.

Lubrication

When pump is operated on daily basis, the manufacturer

recommends installing an inline oiler and air dryer. Use SAE

grade oil (5W to 30W).

Storage

1. When not in use, depressurize and disconnect hydraulic

hoses from application.

2. Wipe clean, thoroughly.

3. Store in clean, dry environment. Avoid temperature

extremes.

4. For transportation or long storage, replace the air vent plug

with shipping plug.

5. Shield pump with a protective cover.

!

!

OPERATION

To reduce the risk of personal injury and/or property

damage, hydraulic connections must be securely fastened

before building pressure in the system. Release all system

pressure before loosening any hydraulic connection in the

system.

Always monitor pressure, load or position using

suitable equipment. Pressure may be monitored by means of

an optional manifold and gauge. Load may be monitored by

means of a load cell and digital indicator. Correct application

position can only be determined by the operator of the

equipment.

1. Air connection: Remove plug from first or second air input

port (refer to figure 1) and connect to adequate air supply.

Install hex plug on unused air input port to prevent air

leakage.

2. Hydraulic connection: Remove manifold plug from oil

output port and connect to suitable application using 3/8

NPT connection.

3. To operate pump, press and hold on the advance button of

the remote control until desired pressure, load or position

is reached. Always monitor pressure, load or position

using suitable equipment. Pressure may be monitored by

means of an optional manifold and gauge (contact

BVA

Hydraulics). Load may be monitored by means of a load

cell and digital indicator. Correct application position can

only be determined

by the operator of the equipment.

4. To retract application, simply press the retract button on

the remote control.

Note: Both air input ports use a 1/4 NPT air nipple (not

included). It is recommended to install an inline air filter and

dryer upstream from the pump to provide clean, lubricated air.

Contact BVA Hydraulics for necessary accessories.