TROUBLESHOOTING GUIDE

The following information is intended as an aid in determining if problem exists. Pumps should be repaired only by authorized

BVA Service Center. For repair service, contact service center in your area.

Symptom

Possible Causes

Corrective Action

Application does not extend, move or

respond to pressurized fluid

• Overload condition

• Loose couplers

• Faulty couplers

• Pump malfunction

• Inadequate air supply

• Remedy overload condition

• Tighten couplers

• Replace couplers

• Contact service center

• Ensure air source can dedicate

7.8 CFM @ 110~175 PSI

Application responds to pressurized

fluid, but system does not maintain

pressure

• Overload condition

• Pump or valve malfunction

• Application/connection leaking

• Remedy overload condition

• Contact

Service Center

• Replace application/connection

Application responds slower than

normal

• Loose connection or coupler

• Restricted hydraulic line or fitting

• Application/connection leaking

• Tighten connection or coupler

• Clean and replace if damaged

• Replace application/connection

Application does not return fluid to

pump (i.e. cylinder will not retract)

• Malfunctioning coupler, damaged ap-

plication

Secure load by other means.

Depressurize pump and hose,

remove coupler and/or application,

then renew or replace

Application does not fully extend (cyl-

inder or spreader)

• Reservoir overfilled

• Fluid level in pump is low

Secure load by other means.

Depressurize pump and hose,

remove application, then drain fluid to

proper level

Secure load by other means.

Depressurize pump and hose,

remove application, then fill fluid to

proper level

Poor performance

• Fluid level in pump is low

• Ensure proper fluid level

5