Speed dome controlling port description:

Pin assignment:

RS-485 & Relay out

R1: Relay #1 out R2: Relay #2 out R3: Relay #3 out

Y: Transmitter (TX +) Z: Transmitter (TX-) A: Receiver (RX+) B: Receiver (RX-)

Relays output: Connect one voltage line and ground of Controller (Such as light) to

the desired “Relay output” number of Control Board.

RS-485: Connect to NC-180AZ PTZ Receiver or Speed dome camera.
Dip switch of Control Board:

The dip switch for the bound rate setting, please refer to the table as below:

Digital input Module:

G1 – G3: Common 1: Sensor #1 in 2: Sensor #2 in 3: Sensor #3 in

4: Sensor #4 in 5: Sensor #5 in 6: Sensor #6in 7: Sensor #7 in

8: Sensor #8 in 9: Sensor #9 in 10: Sensor #10 in 11: Sensor #11 in

12: Sensor #12 in 13: Sensor #13 in 14: Sensor #14 in 15:Sensor #15 in

16: Sensor #16 in

Sensors in: Each sensor-in port can receive trigger signals from other device to

trigger video recording, alarm and notify function. Please use the dry contact for

the sensor in; otherwise it will cause the damage of sensor input.

Baud rate

Pin

1200 2400 4800 9600

Pin 1 & Pin 2

Short Open Short Open

Pin 3 & Pin 4

Short Short Open Open