4.8 HOW TO EDIT COUNT FROM OPERATOR SCREEN

Locate the OPERATOR screen, position cursor next to the Count, enter new value, and press the “ENTER” key. Enter
0” for continuous run.

L e n g t h 1 . 0 0 0
C o u n t C o n t . R u n
L e n g t h A d j u s t m e n t <
P r e s s O P E R t o e x i t

4.9 HOW TO MICRO ADJUST LENGTH USING LENGTH ADJUSTMENT

Locate the OPERATOR screen, position pointer next to the Length Adjustment and press the “ENTER” key.

L e n g t h 1 . 0 0 0
C o u n t C o n t . R u n
L e n g t h A d j u s t m e n t <
P r e s s O P E R t o e x i t

L e n g t h 1 . 0 0 0
U s e A r r o w K e y s t o
A d j u s t L e n g t h
P r e s s O P E R t o e x i t

Adjust Length using

and keys and then press “OPER” to exit adjusting.

4.10 HOW TO SYNCHRONIZE PRESS AND PLS

Open Set-Up screens, find Press offset parameter, and verify its value is set to “0” and if it is not, set it so. Recycle the
power

.

P L S C o u n t s / R e v 1 0 2 4
P r e s s O f f s e t 0

S E T U P - E x i t B K S P - P r e v

Jog the press to its “0” degree (TDC) position, open status screen and read PLS position.

T o o l # P o s : 3 2 4
M a n u a l M o d e
3 0 / C o n t . R u n
P r e s s a M o d e K e y

Go back to Press offset parameter and change it to match PLS reading.

P L S C o u n t s / R e v 1 0 2 4
P r e s s O f f s e t 3 2 4

S E T U P - E x i t B K S P - P r e v

Recycle the power. Read PLS position from the status screen, it should be the same as the press’, “0” degrees.