3 “setup” key – PA Industries Magnum Servo Roll Feed SRF-M12/18/24/32/36/48 - Operation Manual User Manual

Page 13

Advertising
background image

ULTRA MAGNUM SERVO ROLL FEED 5

/23/2003

13

D e l e t e T o o l # 1
P r e s s 1 t o c o n f i r m
A n o t h e r k e y t o a b o r t

The corresponding message on the next screen confirms the chosen command execution.


T o o l # 1 D e l e t e d

or


A b o r t e d !

Display will show STATUS screen.

T o o l # 1 S p d : 3 8 4
A u t o M o d e
3 0 / C o n t . R u n
P r e s s a M o d e K e y


NOTE: To exit tool editing at any time, press the “OPER” key. Changes will not be saved.

3.3 “SETUP” KEY

“SETUP” key controls the appearance of setup screens. Seven screens contain parameters of the feed that are not
changed often or never are changed. Press “SETUP” key three times to open the first screen. Position the cursor on
the desired line, using

and keys , enter in desired value and press the “ENTER” key. Press “SETUP” key to

open the next screen or “ BKSP” – the previous.

J o g S p e e d % 5
J o g A c c e l 1 0 . 0
J o g D e c e l 1 0 . 0
P r e s s S E T U P f o r n e x t

Jog speed is the maximum jogging speed. It is a numeric entry with a range of 0 to 99 percent of the Speed
parameter. Normally set between 1-5%.

JogAccel is the rate of jogging acceleration. It is a numeric entry with a range of 0 to 300 in/sec

2

(0 to 7620 mm/sec

2

).

Normally set 10 in/sec

2

(254 mm/sec

2

).

JogDecel is the rate of jogging deceleration. It is a numeric entry with a range of 0 to 300 in/sec

2

(0 to 7620 mm/sec

2

).

Normally set 10 in/sec

2

(254 mm/sec

2

).

Advertising