STEP 7

Remove the “Air Valve Spool” from

the main “Air-Valve Assembly”.

STEP 8

Using the pick, remove the “Lip

Seal (Air Valve)” from the main

“Air-Valve Assembly”.

STEP 9

Using the pick, remove the

second “Lip Seal (Air Valve)” from

the main “Air-Valve Assembly”.

To assemble the air valve, reverse the order of disassembly. During

assembly, ensure that the open side of the lip-seals are both facing

each other inward. Lubrication of the air valve assembly, with a non-

synthetic lubricant, is recommended in order to facilitate re-assembly

into the intermediate. Lubrication is not necessary for pump operation.

Magna-Lube or Magna-Plate are recommended for assembly lubrication

(see detailed parts list for ordering information).
Note that if the lip-seals are installed incorrectly, they will be unable to

rotate. Insert the spool, hole side first. Then install the air-valve end

plug in the bottom of the Air-Valve Assembly.