Kaiser EG63... User Manual

Page 10

Advertising
background image

10

EN













CONVERSION TO A DIFFERENT TYPE OF
GAS


Before converting the appliance for operation with
a different gas type, check which type of gas it is
currently set to operate with (adhesive label

1 on

appliance).
For the correct nozzle diameter, refer to the table
“Nozzle Table”.
Conversion to a different gas type must be carried
out by qualified technicians and in conformance
with the requirements.


Conversion procedure:

• Disconnect the electrical power supply to

the appliance,

• Change the main oven nozzle:


1. Remove the burner cover plate (see

«Removal of the burner cover plate»),

2. Remove the screws securing the oven

burner

2 and with draw the burner from the

support together with the heat sensor and
the ignition spark plug,

3. Remove the nozzle using a 7 mm box

wrench

3,

4. Screw the new nozzle in fully (diameter in

hundredths of millimetre stamped on the
nozzle), taking care not to cross the thread,

5. Loosen the screw

4 and adjust according

to table the opening size a for air supply by
rotation of the sleeve

5,

6. Tighten the screw

4,

7. Replace the burner reversing the

operations in step 2 above,

8. Replace the cover plate.


NOZZLE TABLE


TABLE OPENING SIZE

Burner

Rated load

kW

Nozzle bore in mm

G20/20

G30/29

Oven

burner

2,50

1,18

0,77

Type of gas

Natural gas

Liquid gas

Size

a

, mm

6,4

15,0

1

2

3

4

5

Advertising