CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.

INDICATION

In the event of errors or faulty operation, the writing

r.P.:

ap

pears on the display : shift the gauge to the

rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press

to cancel it.

6.4.2 Diameter gauge

E

Display the SETUP menu

P

1. ress

to view the diameter gauge CALI

BRATION

function.

m

Place the round part of the gauge terminal on the

flange as shown in the figure and press

Th

2.

e number 28 ± 3° appears on the left display .

Turn

3.

the gauge downward position the round part

of the gauge terminal at 40 mm (radial distance)

from the flange as indicated in the figure; alternati

vely use one of the cones provided as shown in the

images

The nu

4.

mber 290 ± 3° should appear on the left

display. The calibration is already correct.

If not, press the

button holding the gauge still at 40

mm: the number 290 appears on the left display.
Return the gauge to rest position.

Setup