4 - CONTROLS AND COMPONENTS

4.1 - Brake pedal

This pedal allows the operator to hold the
wheel when fi tting the counterweights.

It

must not be actuated during the mea-
suring cycle.

4.2 - Automatic distance and diameter gauge

This gauge allows measurement of the distance of the wheel from the machine and the wheel diameter at the point of
application of the counterweight. It also allows correct positioning of the counterweights on the inside rim by using the
specifi c function (see

INDICATION OF EXACT CORRECTION WEIGHT POSITION

) which allows reading, on the monitor,

the position used for the measurement within the rim (for calibration, see the corresponding section).

4.3 - Automatic width gauge (optional)

Width gauging is through a SONAR device which measures the distance of the wheel without mechanical contact,
merely by closing the guard and each time a valid measurement has been made with gauge

AUTOMATIC DISTANCE

AND DIAMETER GAUGE

.

4.4 - Automatic wheel positioning

At the end of the spin, the wheel is positioned according to the unbalance on the outside or else according to the static
unbalance (when selected).
Accuracy is ± 20 degrees.

4.5 - Keyboard

N.B.: Press the buttons with the fi ngers only: never use the counterweight pincers or other

pointed objects.

When the beep signal is enabled (see section

ACOUSTIC SIGNAL

), pressing of any push

button is accompanied by a “beep”.

The TFT monitor is NOT a TOUCH SCREEN type.

FUNCTION KEYS: they directly select the function on screen

Starts measuring
cycle

Selection of special
function

Confi rm

Stops machine
cycle