Setup, 1 - menu, 2 - balancing machine calibration – CEMB USA K8 (C) User Manual

Page 8

Advertising
background image

I 0668 - 8

a

b

c

d

e

GB

5

.1 - MENU

Use to customise a number of functions on the machine as well as for calibrations.

5

.2 -

BALANCING MACHINE CALIBRATION

To calibrate the machine, operate as follows:

Fit a medium-sized wheel with steel rim on the shaft. Example: 6” x 15” (± 1”) best with less then 20 g unbalance.

Take the exact measurements of the wheel mounted as described in

PRESETTING OF WHEEL DIMENSIONS.

P

RESETTING

OF

INCORRECT

DIMENSIONS

WOULD

MEAN

THAT

THE

MACHINE

IS

NOT

CORRECTLY

CALIBRATED

,

THEREFORE

ALL

SUB

-

SEQUENT

MEASUREMENTS

WILL

BE

INCORRECT

UNTIL

A

NEW

SELF

-

CALIBRATION

IS

PERFORMED

WITH

THE

CORRECT

DIMENSIONS

!

Perform a manual spin under normal conditions

a.

b. Add a 60 gr. (2.00 oz) sample weight on the out

side in any angular position


c. Shift the sample weight from the outside to the

inside keeping the same angular position.

d. Turn the wheel until the sample weight is in the

12 o’clock position.

e. END OF CALIBRATION

CANCELS CALIBRATION IN ANY PHASE.

SETUP

diameter unit of

measure mm/inch

width unit of

measure mm/inch

start from

guard closing

approximates

1-5g 0.1-0.25oz

RETURN TO MEASUREMENT SCREEN

See chapter on

AUTODIAGNOSTICS

See chapter on

BALANCING MACHINE CALIBRATION