Installation and operation instructions, Important general safety information, Pre-installation – Amtrol SPT-28 User Manual

Page 2: Installation, Maintenance, Operation

Advertising
background image

Pre-Installation

1. Visually inspect the Surge-Trol for any damage. If

damage exists return product for replacement.

2. Remove air cap.
3. For applications with pump start-up creating water

hammer adjust the factory pre-charge setting to 15%
below static pressure.

4. For applications with surge issues created by pump

shut down adjust the factory pre-charge setting to
50% below static pressure.

5. For applications with quick closing valves, please

consult manufacturer for tank location and pre-charge
settings. (401) 535-1216.

6. Replace and tighten cap on air valve.

If adjusting the pre-charge pressure
higher than 55 PSIG the unit must be

tied to the system immediately. Failure to do so could
damage the bladder and void all warranties.

Installation

1. The Surge-Trol should be installed as close to the

offending fixture as possible in applications where
there are issues with a quick closing valve.

2. The Surge-Trol should be installed as close to the

pump as possible in surge applications.

3. Once the Surge-Trol is installed and the pre-charge

adjusted properly, check for any leakage. Make repairs
if necessary

Maintenance

1. A qualified professional should check the complete

system, including the Surge-Trol, yearly and more
frequently as the system ages.

Operation

1. The Surge-Trol is designed to provide surge protection

as well as provide a cushion to prevent water hammer
depending on its application.

2. Water temperature is not to exceed 240°F. or fall

below 35°F.

3. The factory pre-charge setting is 25 PSIG and should

only be adjusted at the time of the installation.

4. System velocity shall not exceed 22 fps.

TYPICAL INSTALLATION

PUMP

CHECK VALVE

TO SYSTEM

SURGE-TROL

Diagram 1

EXPLOSION OR RUPTURE HAZARD A

relief valve must be installed to prevent

pressure in excess of local code requirement or maximum

working pressure designated in the Product Manual, whichever

is less. Do not expose Product to freezing temperatures or

temperatures in excess of 240° F. Do not exceed maximum

allowable working pressure 275 psig. Do not adjust the pre-

charge or re-pressure this Product except for any adjustments

required at the time of initial installation, especially if Product is

corroded, damaged or with diminished integrity. Adjustments to

pre-charge must be done at ambient temperature only. Failure

to properly size the Product or follow these instructions may

result in excessive strain on the system leading to Product

failure, serious or fatal personal injury, leakage and/or property

damage.

This Product, like most Products under

pressure, may over time corrode. weaken and

burst or explode, causing serious or fatal injury, leaking or

flooding and/or property damage. To minimize risk, a licensed

professional must install and periodically inspect and service the

Product. A drip pan connected to an adequate drain must be

installed if leaking or flooding could cause property damage. Do

not locate in an area where leakage of the tank or connections

could cause property damage to the area adjacent to the

appliance or to lower floors of the structure.

Chlorine & Aggressive Water. The water

quality can significantly influence the life of

this product. You should test for corrosive elements, acidity, total

solids and other relevant contaminants, including chlorine and

treat your water appropriately to insure satisfactory performance

and prevent premature failure.

Note: Inspect for shipping damage and notify freight carrier

or store where purchased immediately if damage present. If

the product appears to be malfunctioning or shows signs of

corrosion, call a qualified professional. Current copies of the

product manual can be viewed at www.amtrol.com. Use proper

safety equipment when installing.

GENERAL SAFETY INFORMATION -

ADDITIONAL SPECIFIC SAFETY ALERTS

APPEAR IN THE FOLLOWING INSTRUCTIONS.

CALIFORNIA PROPOSITION 65 WARNING:

This product contains a chemical known by

the State of California to cause cancer and to cause birth defects

or other reproductive harm. (California Installer/Contractor -

California law requires that this notice be given to consumer/end

user of this product.) For more information: www.amtrol.com/

prop65/htm.

DO NOT USE OXYGEN - EXPLOSIVE!

Protect against freezing temperatures. Never

pre-charge below 50% of maximum system pressure.

INSTALLATION AND OPERATION INSTRUCTIONS