Installation Instructions

FHP110, FHPV

5

INSTALLATION AND ASSEMBLY

WARNING:

FAILURE TO PROVIDE ADEQUATE

STRUCTURAL STRENGTH FOR THIS COMPONENT CAN
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE
TO EQUIPMENT! It is the installer’s responsibility to make
sure the structure to which this component is attached can
support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
FHP110 or FHPV.

The FHP110 and FHPV ceiling mounts are designed for
attachment to a 2" x 4" or larger wood framework ceiling.

WARNING:

Do NOT attach to vertical mounting surfaces

such as walls or angled ceilings!

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

LIFT FALLING CAUSING SEVERE PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! It is the installer’s responsibility
to make certain the structure to which the mount is being
attached is capable of supporting five times the weight of the
FHP110 or FHPV mount and all attached equipment.
Reinforce the structure as required before installing the
mount.

NOTE:

The following instructions assume a suitable mounting

structure and surface exists prior to installation.

Installing to a Wood Framework (Joists)

1.

Using the ceiling plate (A) as a template, mark mounting
locations and drill 1/4" pilot holes at marked locations.

2.

Use 3/8” x 3” (minimum) Grade 2 lag screws (not provided)
to secure ceiling plate (A) to the joists or wood framework,
using the bolt holes noted. (See Figure 1) for dimension
details.

NOTE:

If using only two bolt holes for mounting, two opposing
holes must be used.

Figure 1

Installing FHP110 or FHPV Mount Assembly

1.

Remove outer column with pipe adapter from ceiling mount
assembly (H).

2.

Install outer column with pipe adapter into ceiling plate of
threaded collar until tight, with a minimum of four threads
engaged. (See Figure 2)

3.

Install 5/16-18 x 1/4” set screw (B) into hole on ceiling plate
(A) to secure outer column. (See Figure 2)

Figure 2

Installing the Display

The FHP110 or FHPV may be used with displays having a
VESA flush or recessed mounting pattern.

VESA Compliant Flush Mounting

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Using screws of
improper size may damage your display. Properly sized
screws will easily and completely thread into display
mounting holes. If spacers are required, be sure to use longer
screws of the same diameter.

CAUTION:

If monitor uses a screw size other than M4, DO

NOT use the M4 screws provided. Using the wrong screws
could result in damage to your display.

1.

Carefully lay display face down on a covered surface to
prevent damage to display.

1 1/2" NPS

2.00

50.800

127

5.00

127

5.00

101.600

4.00

4.00

101.600

4X

9.931

.39

2.00

50.800

(A)

(B) x 1

3

2

(A)

Outer column

Pipe adapter

Advertising