ACT Meters GOLD-PLUS 6V/12V Battery Tester User Manual

Page 12

Advertising
background image

Operating Voltage

6V and 12V DC

Reverse Polarity Protection

Red LED Indication

Max Input Voltage

15VDC

Battery Types

SLA (AGM), GEL & Flooded (WET)

Battery Sizes

6V (1.2Ah – 12Ah) and 12V (1.2Ah to 100Ah)

Ah Capacity Test

Simulated 20 hour (C20) load test to 10.50VDC

Ah Calibration

Calibrated at 0 (zero) position to brand new fully
charged premium brand SLA batteries rated at

Ah Result

Based on the battery under test temperature and
state of charge

Ah Adjustment

Provides ± Ah adjustment to brand new fully charged
standby SLA, cyclic GEL and car FLOODED lead acid
batteries

Battery Table

Recharge or replace battery when Ah capacity
available falls below 65% of the battery’s stated
capacity

Display Type

Back-lit LCD

Flat Battery Warning

6V <5.30VDC, 12V <10.50VDC

Repeat Test Operation

Can perform repeat tests continuously

DCV Accuracy

± 2% of displayed reading

Ah Accuracy

± 10% Fully charged premium brand C20hour rated
SLA batteries at 20 - 25C (68F - 77F)

Applied Pulse Load

6A 1.2Ah - 7Ah, 18A 8Ah - 100Ah

Ah Cal Adjustment

Approx ± 25 dgts

Case Construction

High impact ABS

Size

210(H) x 110(W) x 41(D)mm

EN 61326-1:2006, Class B (Emissions)

EN 55011:2007, A2 Radiated Emissions Only

EN 61326-1:2006, Basic Requirements (Immunity)

EN 61000-4-2: 1995, A1, A2

EN 61000-4-3: 2006, A1

2004/108/EC (Where Applicable)