BATMASTER

inHouse Calibration Test Box
for ACT Intelligent Battery Testers

Operating Instructions

Calibrated

Multimeter

+

-

POWER

CHARGING

READY BATMASTER

ON

WAIT

TEST

BATTERY

BATMASTER

INHOUSE CALIBRATION TEST BOX

Operating Instructions

1.

Connect power supply and switch AC on. Yellow power LED will
illuminate.

2.

Wait for AMBER charging LED to stop flashing

3.

When GREEN LED shows, connect calibrated multimeter and switch
to 20V DC range.

4.

Connect battery tester clips tightly to posts, RED + BLACK -

5.

During battery tester power up, allow multimeter voltage to stablise, then
compare voltage with battery tester. Pass equals ±5% of multimeter
reading.

6.

Record battery tester Ah reading Pass = 7Ah - 9Ah

7.

Replace battery tester leads if Ah reading is low or erratic. IMPORTANT:
BATMASTER operating temperature 20°C - 30°C (68°F - 86°F)
Replace BATMASTER internal battery (Yuasa NP7Ah-12V) when RED
LED indicates.

+

-

RED/GOLD-IBT

OR

GOLD-PLUS

ONLY

Verify accuracy of all ACT Intelligent Battery Testers with BATMASTER.
This InHouse bench tester allows the engineer to check accuracy at
any time and carry out recalibrations when necessary. A cost effective
solution for those who have many ACT battery testers in service.