CANopen Industrial Datasheet

Version 20130503

INDUST RIAL I NCLI NOME T ER

CA NOPE N INT ERFA CE

Technical Data

Electrical Data

Model

INC-080

INC-360

Measurement Range

± 80°

360°

Number of Axes

2

1

Resolution

0.01°

Accuracy (T = -10 °C to +40 °C)*

0.1°

Sensor Response Time

10 ms (without filter)

Recommended Measurement Rate

Up to 10 Hz

Interface

CANopen (In Conformance to DS410)

Transceiver According ISO 11898,

Galvanically Isolated by Opto-Couplers

Transmission Rate

Adjustable: Max. 1 MBaud

(Factory Setting : 125 kBaud)

Addressing

Programmable Node-id from 1 to 127 (Factory Setting: 1)

Supply Voltage

10 to 30 VDC (Absolute Maximum Ratings)

Current Consumption

Max. 57 mA at 10 V DC; Max. 53 mA at 24 V DC

EMC

Emitted Interference: EN 61000-6-4

Noise Immunity: EN 61000-6-2

Connection

Connector Output, 5 Pin M12 male (A-coded)

Mechanical Data

Housing Material

Glass Fiber Reinforced PBT (Polybutylene Terephthalate)

Potting Material

Polyurethane

Shock (EN 60068-2-27)*

100 g (half sine, 6 ms)

Vibration (EN 60068-2-6)*

1.5 mm (10Hz to 58Hz) &

20 g (58 Hz to 2000 Hz)

Weight

75 gm / 3 oz

Environmental Conditions

Operating Temperature

-40 °C to +85 °C / -40 °F to 185 °F

Humidity

98 % Relative Humidity, Non-Condensing

Protection Class (EN 60529)

IP 69K (With Appropriate Counter Connector) , IP68, IP67

*further data available on request