BEI Sensors Divide-By Module User Manual

Electronic modules, Bei sensors, Divide-by module

Advertising
background image

Electronic Modules

Divide-By Module

BEI Sensors

7230 Hollister Avenue

Goleta, CA 93117

www.beisensors.com

Tel: 800-350-2727

Fax: 805-968-3154

Specification No.:09166-016

Rev 3-18-14

Electronic Modules

Divide-By Module

BEI Sensors

The Divide-By Module option provides a method to divide the effective resolution and signal

frequency of a quardrature output incremental encoder. The Divide By option is available

with the BEI Optical Isolator and Broadcaster. The module receives quardrature counts

from an incremental encoder and divides them by a predetermined integer value. The index

signal is passed through without modification. When combined with the Optical Isolator a

single encoder can be used to feed different control devices, synchronizing their outputs at

different ratios. This can lower parts count and reduce overall system costs.
This module accepts single ended or differential inputs and divides the signal by a factory set

number from 2 to 256. The resulting output signal is a reduced resolution of the input signal.

Ideal for use in machine retrofitting and for applications where a different resolution output is

needed from the same encoder source. When ordering, make sure to specify the divide-by

amount in the model number (see ordering options below).

Divide By Module Ordering information

FOR ASSISTANCE CALL 800-350-2727

SAMPLE: EM - DR1 - DB2 - 5 - 28V/V

Specifications

Power:

The optical isolator can accommodate standard operating voltages from 5 to 28 VDC. It should

never be connected directly to AC power mains. The module draws approximately 75 mA and a

green LED indicates the unit is powered. The optical isolator module does not provide power to

the encoder. Any encoders used in conjunction with this module must be connected to their own

power.
Signal:

Specifying an optical isolator module requires knowledge of three system parameters: the DC

supply voltage available in the system; the encoder output type (logic levels and driver type); and

the input signal specifications of the receiving electronics.

Output Code Format From Encoders

Dual Channel in quadrature plus index and complements. Data lines are designated A, B, Z, A/, B/,

Z/ at the module
Output Signal Type From Encoder

Differential line driver (Use Connection Instructions #1)

Single ended line driver (Use Connection Instructions #2)

Single ended open collector with pull-up resistors internal to encoder (Use Connection Instructions

#3)

Single ended, open collector (Use Connection Instructions #3)
Output Signal Voltage Level From Encoder

5 VDC (TTL, RS422 compatible, line driver)

12-15 VDC

24VDC
Frequency Response of Optical Isolator
1 MHz, maximum
Power Requirements For Optical Isolator

5-28 VDC ±5%, 75mA plus load current
Optical Isolator Output Options

28V/V Line Driver, 100mA source/sink, Vout = Vin

28V/5 Line Driver, 100mA source/sink, Vout = 5V (Derate output current to 50mA with supply

voltage > 12VDC)

28V/OC NPN Open Collector, 80mA sink

Protection Level

Supply lines protected against over voltage to 60 volts and reverse voltage

Tristate Outputs

Available as –S Special Feature

EM

DR1

TYPE:

EM = Electronic Module,

DIN Rail mount

FUNCTION

DB = Divide By

OUTPUT TERMINATION:

TB = Terminal Block

VOLTAGE/OUTPUT:

28V/V:28 V maximum, Vout=Vin
28V/5:28V maximum, Vout=5V
28V/OC:28V maximum, Vout=Open Collector

DB

TB

DIVIDE BY FACTOR:

Integer Value from 2 to 256

PACKAGE STYLE:

DR1 = 114.5 mm x 99mm x 22.5 mm

5

OUTPUT VOLTAGE FROM

ENCODER

3=2.5-3.7 V Logic

5=3.7-6.8 V Logic

15 = 11-19V Logic =

24 = 19-29V Logic =

Mechanical

Package dimensions are 114.4 mm high by 99 mm wide by 22.5 mm thick. The package

mounts to a DIN rail type EN 50 022 (35mm X 7.5mm). A length of DIN rail is supplied with

each module. The module simply snaps directly to the DIN rail and is ready to use.