Electronic Modules

Divide-By Module

BEI Sensors

7230 Hollister Avenue

Goleta, CA 93117

www.beisensors.com

Tel: 800-350-2727

Fax: 805-968-3154

Specification No.:09166-016

Rev 3-18-14

Connection Instructions #3

Open Collector with or without Internal Pull-up Resistors

Encoder NPN (sinking) outputs. Connect encoder output A to optical isolator module input A/, B to B/ and Z to Z/. Connect the A, B, and Z inputs of the optical

isolator to the auxiliary output terminal on the optical isolator module for 5V module and to higher voltage when specified by module model and part number. This

connection results in a logic inversion within the optical isolator module. To compensate for the logic reversal, swap A for A/, B for B/, and Z for Z/ at the optical

isolator outputs.