Caution – EBARA EFQT8 User Manual

Page 32

Advertising
background image

EBARA Fluid Handling 31

























Figure 5. Cartridge Seal Assembly



















CAUTION!

This seal is not designed for operation at
temperatures above 160 º F (71º C). Do not use
at higher operating temperatures.


If the seal plate was removed, install the seal plate
gasket (2). Position the seal plate over the shaft and
secure it to the bearing housing with the hardware.

To prevent damaging the shaft sleeve O-ring (22) on
the shaft threads, stretch the O-ring over a piece of
tubing 1-1/4 I.D. x 1-1/2 O.D x 2 inches long (32mm
x 38mm x 51mm).

SEAL PL ATE

O-RINGS

SLEEVE

O-RING

INTEGR AL
SH AFT
SLEEVE

SHEAR
RING

(SHEARED)

ST ATION ARY

SEAT

ST ATION ARY

ELEM ENT

ROT AT ING
ELEM ENT

DRIVE BAND

SPRING

CENTERING

W ASH ER

BELLOW S

IM PELLER

SH AFT

IM PELLER

SHIM S

IM PELLER

SPRING

R AT AIN ER

Advertising