EBARA EFQT8 User Manual

Page 6

Advertising
background image

EBARA Fluid Handling 5

INSTALLATION – SECTION B













OUTLINE DRAWING























Figure 1 Pump Model EFQT-8

Review all SAFETY information in Section A.

Since pump installations are seldom identical, this
section offers only general recommendations and
practices required to inspect, position and arrange
the pump and piping.

Most of the information pertains to a standard
static lift application where the pump is
positioned above the level of liquid to be pumped.

If installed in a flooded suction application
where the liquid is supplied to the pump under
pressure, some of the information such as
mounting, line configuration, and priming must be
tailored to the specific application.

Since the pressure supplied to the pump is critical to
performance and safety, be sure to limit incoming
pressure to 50% of the maximum permissible
operating pressure as shown on the pump
performance curve.

For further assistance, contact your EBARA
distributor or EBARA Fluid Handling.

Pump Dimensions

See Figure 1 for the approximate physical
dimensions of this pump.

Advertising