Warning – EBARA EFQU4 User Manual

Page 19

Advertising
background image

EBARA Fluid Handling

18

TROUBLESHOOTING - SECTION D


Review all SAFETY information in Section A.

















TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS

TO PRIME

Not enough liquid in casing.

Suction check valve contaminated or
damaged.

Air leak in suction line.

Lining of suction hose collapsed.

Leaking or worn seal or pump gasket.


Suction lift or discharge head too high.


Strainer clogged.

Add liquid to casing. See PRIMING.

Clean or replace check valve.


Correct leak.

Replace suction Hose.

Check pump vacuum. Replace leaking
Or worn seal or gasket.

Check piping installation and install bypass line if
needed. See INSTALLATION.

Check strainer and clean if necessary.



WARNING!

Before attempting to open or service the

pump:

1. Familiarize yourself with this manual.
2. Lock out or disconnect the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to cool if overheated.
4. Check the temperature before opening

any covers, plates, or plugs.

5. Close the suction and discharge valves.
6. Vent the pump slowly and cautiously.
7. Drain the pump.

Advertising