EBARA Submersible Slurry Pump

ENZX

Operating, Installation and Maintenance

Operating Features

a. Motor is protected by double mechanical seal and lip seals to prevent the entry of water and other impurities

into motor.

b. An agitator fitted on the end of main impeller mixes the solid and liquid, allowing the pump to lift the liquid

and solid together. The wet parts of the pump are constructed of a hard chrome iron material (56.8 HRC)
designed to prolong service life.

c. Motor and pump are submersed in liquid, saving installation space, protecting the equipment, allowing ease

of maintenance, and greatly reducing operating noise.

d. The motor has been designed to include several internal protection measures; refer to chart below:

Notes:

1. All protection devices are low voltage device (

36V). Please check the open and close of device or resistance

to earth by multimeter.

CAUTION!

High voltage testers should not be used. This will result in damage to the protection device.

WARNING!

2. If wired to an alarm type control box properly, the protection devices will automatically stop the pump when a

failure is detected.

Standard Connections

EBARA

Fluid Handling

www.pumpsebara.com

5

(803) 327-5005 • (803) 327-5097

(fax)

rev. 03/14

Protection Devices

HP Range

Location

Device

No. of

Wires

Open/

Closed

Signal

All

Winding Wire

Thermal Protector

2

N.C.

Alarm

7.5 to 20 Bottom of motor chamber

Leakage Detector

(Float Switch)

2

N.O.

Alarm

30

Bottom of motor chamber

Leakage Detector

(Resistance Device)

1

-

Alarm

Power Cable

7.5 - 20 HP models

Sensor Cable

7.5 - 20 HP models

L1

(r

ed

)

L2

(w

hi

te

)

L3

(b

la

ck

)

G

ro

un

d

(g

re

en

)

Le

ak

ag

e

De

te

ct

or

(

or

an

ge

, b

la

ck

)

Th

er

m

al

Pr

ot

ec

to

r

(r

ed

, w

hi

te

)

G

ro

un

d

(g

re

en

)

Power Cable

30 HP models

L1 L2 L3 G

ro

un

d

Le

ak

ag

e

De

te

ct

or

Th

er

m

al

P

ro

te

ct

or

U V W

JH W

C

W

C

G

Advertising