3 switching off the boiler, Precautions to take if there is a danger of frost – DE DIETRICH DTG 230 User Manual

Page 11

Advertising
background image

11

09/03/2011 - 300011506-001-D

DTG 230

4. Operating the appliance

4.3 Switching off the boiler

Set the On/Off switch to 0.

„

DIEMATIC-m3 control panel



The panel must always be supplied with 230V voltage:

- to ensure the anti-grip of the heating pump,

- to ensure Titan Active System® operation when a titanium anode

is protecting the DHW tank.

Use the mode:
- summer to shut down the heating.
- antifreeze to shut down the boiler if you are to be absent.

4.3.1

Precautions to take if there is a danger of frost

Heating circuit:
Use a correctly dosed antifreeze to prevent the heating water
freezing. If this cannot be done, drain the system completely. In all
cases, consult the fitter.

Domestic hot water circuit:
Drain the domestic water tank and pipes.

4.3.2

Precautions to take in the event of prolonged shutdown (one year or more)

- Close the gas valve
- The boiler and the chimney must be swept carefully.
- Close the door of the boiler to prevent the internal circulation of air.