BJM Pumps SKX150CSSF-575T User Manual

Page 16

Advertising
background image

16

7) Remove the impeller.
8) Remove the inspection screw for the oil chamber (pos#50-08). Pour

out a small sample of the oil. If it is milky white, or contains water, then
the oil and possible, the mechanical seal, should be changed. If an oil
change is needed.

9) Remove the screws that hold the oil chamber cover in place & remove

the oil.

10) Replace the mechanical seal if necessary.
11) Replace the oil.
12) Assemble the pump.

STATOR REPLACEMENT OR ELECTRICAL REPAIR


The BJM Pumps “F” Series designed pumps utilize unique construction methods and
materials. The interconnection of all wiring requires the use of a BJM wire connection
kit. Included in this kit are specific instructions on how a qualified factory trained and
certified repair technician can perform this work properly. No other materials or methods
should be used on this product.