Pump rotation – BJM Pumps SV1500F-230 User Manual

Page 7

Advertising
background image

7

PUMP ROTATION

If wired properly to the control, the single phase BJM Pumps SV-F Series pump should
operate with the correct pumping rotation. Verification is recommended prior to installing
into the sump basin.

Two ways to check the correct pump rotation:

1. By looking at the impeller; the rotation of the impeller should be counter

clockwise as shown in the picture below.

2. By looking from the top of the pump. Since the impeller cannot be seen, the best

way to check the rotation is to check the kick back motion of the pump when the
pump just starts. The kick back motion of the pump should be counter clockwise
as shown in the picture below.