PUMP OPERATION

This pump is designed to handle dirty water that contains some

solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.

Do not operate this pump where explosive vapors or

flammable material exist. Death or Serious injury may result.

TYPICAL MANUAL DEWATERING INSTALLATION

NOTE: Maximum recommended starts should not exceed 10 times per hour.

MANUAL OPERATION

All SVF models

are provided with a 50’ (15 m) power cable. NEVER splice the power

cable due to safety and warranty considerations. Always keep the plug end dry.

Do not alter the length or repair any power cable with a splice. The

pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.

The BJM Pumps, SV-F series pumps require a special control that contains the starting
components, thermal sensor and Seal Minder connections. These pumps cannot be
directly connected to a power source.

TYPICAL AUTOMATIC DEWATERING INSTALLATION