Assembly

7.

AssEmBly

7.1.

safety instructions

Danger!

danger of explosion!
The device is a closed system. It must not be removed.
The following safety instructions must be observed:
• The surface of the device may become electrostatically charged.

In potentially explosive areas the surface of the devices may be

cleaned with a damp or an anti-static cloth only.

• Only specified cables and lines may be used.
• The operator must ensure an adequate strain relief.
• Lines with an outer diameter of 6 mm - 13 mm can be used.

Observe the maximum thermal load of the installed cables and

lines.

• The inserted seal must be adjusted to the diameter of the cable

/ line.

The rated cross-section of the cables / line cores must be at

least 0.75 mm² and must not exceed 2.5 mm².

• Screws for attaching the cover of the terminal box must be

tightened to a torque of 100 Ncm (± 5 %).

Danger!

risk of electric shock!
Acute risk of injury from hazardous body voltage! Risk of damaging
the device by short-circuit!
• Before reaching into the device or the equipment, switch off the

power supply and secure to prevent reactivation!

• Live terminals in the terminal box may cause an electric shock,

short-circuit or explosion. Switch off the power supply. Only then

open the terminal box.

• The connection lines of the electromagnets must be permanently

installed in such a way that they are adequately protected from

mechanical damage.

• Observe applicable accident prevention and safety regulations

for electrical equipment!

Warning!

danger – high pressure!
When reaching into the system, there is an acute risk of injury.
• Before dismounting pneumatic lines and valves, turn off the

pressure and vent the lines.

• During the installation, make certain the flow direction is correct.
• Observe applicable accident prevention and safety regulations

for pressurized devices.