Application conditions of the devices

Fuse
...A

5.2.

Operation only with associated
valve

The solenoid coils type 74. / 75. may be operated as a complete device
only with associated valve body which satisfies the following requirements:
• Materials for individual and block assembly:

Metal (brass, aluminum, stainless steel) or plastic (e.g. polyamide
PA 6 GV).

Danger!

danger of explosion!
• If devices are used in gasoline pumps to control gasoline as

Category 2, a valve body made of metal (brass, aluminum or stain-

less steel) must be used.

Minimum dimensions of the valve bodies:
• 40 mm x 40 mm x 10 mm (L x W x H)

A larger valve body with better heat conductivity may be attached
at any time.

5.3.

ignition protection type

• For model with installed rubber hose line (A): EX m II T4 (T3 at

+55 °C) or T5 in accordance with EN 60079-0, EN 60079-18.

• For model with terminal box (L and K): EX em II T4 (T3 at +55 °C)

or T5 in accordance with EN 60079-0, EN 60079-7 and
EN 60079-18.

5.4.

dimensions

connection type

length

(mm)

Width

(mm)

height

(mm)

Electrical
connection A

106

40

58

Electrical
connection L and K

121

60

113

5.5.

Protection class

IP65 in accordance with EN 60529.

5.6.

individual assembly

The solenoid coils type 74. / 75. are suitable for individual assembly only.

5.7.

Operating temperature range

For each type observe the operating temperature range specified in
the Electrical Data.

english