Pneumatic data – Burkert Type 8693 User Manual

Page 33

Advertising
background image

33

Description of system,

Input resistance

180 Ω at 4 – 20 mA / 12 bit resolution

for actual value signal

17 kΩ at frequency, 0 – 1000 Hz / 1‰ of measured value

> 300 mV

ss

sine, square, triangle

Pt 100 -20 – +220 °C, resolution < 0.1 °C

Input resistance

180 Ω at 0/4 – 20 mA / 12 bit resolution

for nominal value signal

19 kΩ at 0 – 5/10 V / 12 bit resolution

Protection class

3 in accordance with VDE 0580

Analogue position feedback
max. current
for voltage output 0 – 5/10 V 10 mA
max. load
for current output 0/4 – 20 mA 560 Ω

Inductive proximity switches
current limitation

100 mA

Binary outputs

galvanically isolated

Current limiting

100 mA, output is clocked

Binary input

galvanically isolated

0 – 5 V = log "0", 10 – 30 V = log "1"
input inverted accordingly

11.3.6. pneumatic data

Control medium

neutral gases, air

Quality classes in accordance with DIN ISO 8573-1

Dust content

Class 5

max. particle size 40 µm, max. particle density 10 mg/m³

Water content

Class 3

max. pressure dew point
-20 °C or min. 10 degrees below the lowest operating temperature

Oil content

Class 5

max. 25 mg/m³

Temperature range

0 – +50 °C

Pressure range

3 – 7 bar

Air output, pilot valve

7 l

N

/ min (for aeration and deaeration)

(Q

Nn

value according to definition for pressure drop from 7 to 6 bar absolute)

Optional:

130 l

N

/ min (for aeration and deaeration)

(only single-acting)

Connections

Plug-in hose connector Ø 6mm / 1/4”

Socket connection G1/8

english

Type 8692, 8693

Advertising
This manual is related to the following products: